3. Backhaul
Backhaul Components
To install the Surge Protector:
1 Remove the rubber grommet from the case and cut some slots in it.
2 Thread two Ethernet cables and a ground wire through the grommet and place
the grommet back in the case.
3 Plug the Ethernet cables into the shielded RJ45 jacks. It does not matter which
cable goes to which jack; the unit provides bidirectional protection.
4 Attach the ground wire to the ground lug.
5 Close the case and attach it to the mast with a hose clamp.
6 Attach one of the Ethernet cables to the radio.
7 Attach the other Ethernet cable to the LIU.
8 Attach the ground wire to a nail and press the nail into the ground.
3.2.4 Mast Kit Components
The following table lists the Mast Kit components. The remote and central
backhauls use the same mast kit components.
The Weighted Base
(70-0070) is a separate component (see “Base” on page 34).
CAUTION
Attach the LIU ground wire and the Surge Protector ground wire to the
same nail.
TIP
See “Possible LIU Components” on page 24 for an illustration that
shows the Surge Protector installed on a mast.
Table 3–5 Mast Kit
Fiberglass Kit (15-0004) Aluminum Kit (15-0033) Reference
Mast, fiberglass (55-0008) Mast, aluminum (70-0081) “Mast” on page 34
Base (55-0007) Base (55-0007) “Base” on page 34
Bag (70-0058) Bag (70-0058) “Bag” on page 36
Backpack Kit (15-0014) Backpack Kit (15-0014) “Backpack Kit” on page 36
1 each backpack (70-0059) 1 each backpack (70-0059) “Backpack Kit” on page 36
3 each guy lines, rope, orange,
15.25 meters (70-0057)
3 each guy lines, rope, orange,
15.25 meters (70-0057)
“Backpack Kit” on page 36
3 each tent stake, steel, 12 in
(70-0061) (hard ground
stakes)
3 each tent stake, steel, 12 in
(70-0061) (hard ground
stakes)
“Backpack Kit” on page 36