38 RT System 2 v2.0.0 Deployment Guide R00.e
© 2010-2012 Wireless Seismic, Inc. All rights reserved.
3. Backhaul
Configure the Radios
3.4 Configure the Radios
The FMQuadro™ Web Interface is used to configure the radio channels. The radio
licenses are pre-configured by Wireless Seismic, Inc. This section describes how to
connect the radios to a computer and configure them.
Check the radios before connecting them to any switch.
3.4.1 Create a Private Network
Create a private network between the computer and the Fluidmesh radio.
1 Prerequisites:
● Windows computer
● Browser with Adobe Flash
● AC Power
● PoE Injector
● Two Ethernet Cables
2 Power on the computer.
3 Connect the components (see Figure 3–16 Fluidmesh Radio Private Network on
page 39):
● Plug the PoE injector into an AC outlet.
● Connect the computer to the PoE injector with an Ethernet cable.
● Connect the Fluidmesh radio to the PoE injector with an Ethernet cable. The
radio powers up.
► FM1100 – Connect to LAN 1
► FM3100 – There is only one connector
NOTE
The expected configuration in the RT System 2 system is as follows:
FM1100 = mesh point (remote backhaul)
FM3100 = mesh end (central backhaul)
NOTE
All Fluidmesh units are preconfigured from the factory with an IP
address of 192.168.0.10.
Wireless Seismic, Inc. reconfigures each Fluidmesh radios to have a
unique IP address, identifiable by the sticker placed on the radio.
If the radio is exposed to excessive static electricity, any post-factory-
configured IP address may reset to this factory-configured IP address.