User's Manual

Draft
38 RT System 2 v2.0.0 Deployment Guide R00.e
© 2010-2012 Wireless Seismic, Inc. All rights reserved.
3. Backhaul
Configure the Radios
3.4 Configure the Radios
The FMQuadro Web Interface is used to configure the radio channels. The radio
licenses are pre-configured by Wireless Seismic, Inc. This section describes how to
connect the radios to a computer and configure them.
Check the radios before connecting them to any switch.
3.4.1 Create a Private Network
Create a private network between the computer and the Fluidmesh radio.
1 Prerequisites:
Windows computer
Browser with Adobe Flash
AC Power
PoE Injector
Two Ethernet Cables
2 Power on the computer.
3 Connect the components (see Figure 3–16 Fluidmesh Radio Private Network on
page 39):
Plug the PoE injector into an AC outlet.
Connect the computer to the PoE injector with an Ethernet cable.
Connect the Fluidmesh radio to the PoE injector with an Ethernet cable. The
radio powers up.
FM1100 – Connect to LAN 1
FM3100 – There is only one connector
NOTE
The expected configuration in the RT System 2 system is as follows:
FM1100 = mesh point (remote backhaul)
FM3100 = mesh end (central backhaul)
NOTE
All Fluidmesh units are preconfigured from the factory with an IP
address of 192.168.0.10.
Wireless Seismic, Inc. reconfigures each Fluidmesh radios to have a
unique IP address, identifiable by the sticker placed on the radio.
If the radio is exposed to excessive static electricity, any post-factory-
configured IP address may reset to this factory-configured IP address.