User's Manual

Draft
RT System 2 v2.0.0 66 Deployment Guide R00.e
© 2010-2012 Wireless Seismic, Inc. All rights reserved.
7
7. Batteries
This chapter provides information about the batteries and battery
requirements used in the Wireless Seismic, Inc. RT System 2.
7.1 Lithium Ion Batteries
This section provides information regarding the characteristics, use, and
handling of lithium ion batteries. See the following sections for details:
“Specifications” on page 66
“Handling and Safety Guidelines” on page 67
“Transportation” on page 68
“Storage” on page 69
7.1.1 Specifications
The RT System 2 uses one or two custom intelligent lithium-ion batteries with
self-contained charging circuitry that protects the batteries from overcharge,
discharge, short circuits, or extreme temperature charging.
Battery specifications are shown in the following table:
Table 7–1 Lithium Ion Battery Specifications
Item Description Value
Voltage Nominal 3.7 VDC
Shut-off 2.8 VDC
Full (90%) charge 4.1 VDC
Overcharge Voltage 4.28 VDC
Over Discharge Voltage 2.80 VDC
Current Maximum Charge Current 2 A
Consumption Active Mode 4.2 mA maximum
Consumption Sleep Mode 66 A maximum
Full (90%) charge
mAh
Approximately 12,000
mAh at nominal voltage
Full (90%) charge
mWh
Approximately 44,400
mWh at nominal voltage