Wisen Innovation Technical Doc. No.2019 WISENMESHNET® L-Series Omni Tilt & Distance Sensor Node - User Manual WISENMESHNET® L-Series Omni Tilt & Distance Sensor Node User Manual Model Name:6F08 Wuxi Wisen Innovation Co., Ltd. November 2019 www.wisencn.
Wisen Innovation Technical Doc. No.2019 WISENMESHNET® L-Series Omni Tilt & Distance Sensor Node - User Manual Revision History and Clarification Rev. Issue Date Revisions V1.0 01/11/2019 1 Issue st Written By Revised By Xiaoyan Huang Dr. Yan Wu Document Definition: It defines the specifications (i.e.
Wisen Innovation Technical Doc. No.2019 WISENMESHNET® L-Series Omni Tilt & Distance Sensor Node - User Manual Table of Contents 1. Product Introduction................................................................................................................................................... - 4 2. System Structure Layout ............................................................................................................................................. - 5 3. Node & Radio Features .........
Wisen Innovation Technical Doc. No.2019 WISENMESHNET® L-Series Omni Tilt & Distance Sensor Node - User Manual 1. Product Introduction ® The WISENMESHNET Omni Tilt & Distance Sensor Node is one of the key products in our ® patented WISENMESHNET geotechnical safety monitoring system. Working together with the WISENMESHNET ® gateway product and node products, it intelligently delivers the real-time distance change between any two points in space of a structure to the information centre.
Wisen Innovation Technical Doc. No.2019 WISENMESHNET® L-Series Omni Tilt & Distance Sensor Node - User Manual 2. System Structure Layout Figure 2. System Structure Layout. www.wisencn.
Wisen Innovation Technical Doc. No.2019 WISENMESHNET® L-Series Omni Tilt & Distance Sensor Node - User Manual 3. Node & Radio Features Node Features: Basics 6F07 6F08 Battery Power Qty. x 1 (3.6V Lithium primary D-Cell ER34615) Accuracy Stop Voltage 2.7VDC Mesh Stop Voltage 2.1VDC Battery Connection Standard Aluminium Battery Holder Working Current (DC) Max. 350mA (Typ. 250mA) Local Storage Min. 450 Messages during Meshing LxWxH 100 x 100 x 60mm Weight <= 0.
Wisen Innovation Technical Doc. No.2019 WISENMESHNET® L-Series Omni Tilt & Distance Sensor Node - User Manual IP Rating >= IP66 Operating Temperature -10 to 50°C Radio Features: FCC 915MHz System Radio Band 902-928MHz Central Frequency (Default) 905/910/915/920/925MHz Default Transmit Power 15dBm Receive Sensitivity -112dBm Bandwidth 500kHz Transmission Speed 19.2kb/s No.
Wisen Innovation Technical Doc. No.2019 WISENMESHNET® L-Series Omni Tilt & Distance Sensor Node - User Manual Figure 3. Omni Tilt & Distance Sensor Node Internal Configuration Terminologies, where: No. Terminology 1 Mesh Antenna 2 On/Off Switch 3 Laser Distance Sensor 4 Laser Pointer Switch, i.e., laser constantly on during installation 5 Mesh Program Port 6 ER 34615 3.6V D Cell Battery 5. Operation Procedures 5.
Wisen Innovation Technical Doc. No.2019 WISENMESHNET® L-Series Omni Tilt & Distance Sensor Node - User Manual 5.2.Reading Conversion to Structural Tilt Direction When holding the User Manual page horizontally, then when X-axis arrow rotates around 0-dot into the paper plane, the readings of “x” decreases. Figure 4. Axis marks on the product label. 5.3.Laser Distance Warning and Error Code Warning! A.
Wisen Innovation Technical Doc. No.2019 WISENMESHNET® L-Series Omni Tilt & Distance Sensor Node - User Manual Double Coated Tissue Tape at one side). Once a battery is installed, node is powered on, and lid is screwed on properly. Then glue the cover onto the node as shown in the figure below. It protects the lenses from dust, heat and potential damage.
Wisen Innovation Technical Doc. No.
Wisen Innovation Technical Doc. No.2019 WISENMESHNET® L-Series Omni Tilt & Distance Sensor Node - User Manual readings. The Omni Tilt & Distance Sensor Nodes must be oriented with at least one axis marked on the label parallel to the horizontal plane, so that the tilting angle data can be easily recognized and interpreted. 6.
Wisen Innovation Technical Doc. No.2019 WISENMESHNET® L-Series Omni Tilt & Distance Sensor Node - User Manual b) Check the box lid to see if it is firmly tightened; c) Whether the antenna is bent or damaged and that the node is not blocked by new construction, e.g.
Wisen Innovation Technical Doc. No.2019 WISENMESHNET® L-Series Omni Tilt & Distance Sensor Node - User Manual Before taking any action, please read all the information provided carefully, and keep the guidance documents safe; Ensure that any procedures and installations are correctly carried out. The communication cable and the case must be grounded. This product has been designed to meet a certain water-proof level.
Wisen Innovation Technical Doc. No.2019 WISENMESHNET® L-Series Omni Tilt & Distance Sensor Node - User Manual FCC Warning This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.