User's Manual

Wisen Innovation Technical Doc. No.2019 WISENMESHNET® L-Series Omni Tilt & Distance Sensor Node - User Manual
www.wisencn.com Page - 10 - of 15
Double Coated Tissue Tape at one side). Once a battery is installed, node is powered on, and lid is screwed on properly.
Then glue the cover onto the node as shown in the figure below. It protects the lenses from dust, heat and potential
damage.
Error Code Instructions
Code_Info
Description
Notice
00
Node is working in a good condition
-
01
Target moving too fast or beam interrupt
Repeat measurement, use tripod (@E260)
02
Signal too low or distance out of range
Use special target plate (@E255)
03
Signal too high
Avoid high reflecting surfaces (@E256)
04
Time out on reply
Cable may have gone loose or check if there
is any bad physical connection or too far out
of range (e.g., point to the sky) (Wisen)
05
Single reading achieved
Single success on the sampling procedure.
06
Max-Min>2xError Tolerance
The difference of sample values is too large,
repeat measurement or use tripod. (Wisen)
07
Unknown command or wrong parameter
Use correct syntax (@E203)
08
Error on serial communication
Check communication (@E220)
09
Temperature too high
Cool down module (@E252)
10
Temperature too low
Warm up module (@E253)
11
Voltage supply too low
Improve voltage supply quality (@E254)
12
Too much background light
Protect target against sunlight (@E257)
13
Laser error
Module defect (@E284)
14
APD-voltage can’t be adjusted correctly
Module defect (@E288)
15
Flash configuration error
Power down and up again (@E289)