4. Terminologies
Figure 3. VW Interface Node Internal Configuration Terminologies.
5. Operation Procedures
5.1System Deployment Notifications
1) Location: The deployment location of a VW Interface Node is usually determined by the required monitoring or
inspection location;
2) All the Serial Numbers of a Unit must be recorded against their site references;
3) Before any VW Interface Node is switched on, two tasks will need to be carried out:
A. Unlike the Tilt Node which has a MEMS tilt sensor embedded in the node, the VW sensors chosen by the
customer, e.g., VW crackmeter, VW settlement gauge, VW strain gauge, etc., must be connected to the VW
Interface Node;