User Manual

IEEE 802.11g Access Point User’s Guide
56
Command> enable syslogd
Example:
Command> disable syslogd
Show syslog
Description: This command displays the current configuration of the Syslog facility.
Example:
Command> show syslog
Syslog configuration:
State = enabled
Remote daemon’s IP address = 192.168.168.100
Security
Change password <string>
Description: This command allows the user to change the password that logs on to the
Command Line Interface or the HTTP interface. The password is a character string that starts
with a letter and contains at least 6 and up to a total of 15 alphanumeric characters. The
password is case sensitive. The default factory setting is “password”. If you forget the
password, the only way to recover is to clear the entire configuration and return the unit to its
original state as shipped from the factory – by pressing the hardware factory default button.
Unfortunately, this means that you have to re-enter all of your configuration data.
After the user presses the hardware factory default button, the system will return all settings to
the factory default. The password will once again be “password”.
Example:
Command> change password
Please enter the old password: ********
Please enter the new password: ********
Please re-enter the new password: ********
Set radius server reattempt <min>
Description: This command sets the re-authentication attempt time.
Example:
Command> set radius server reattempt 5
RADIUS server reattempt is 5 minutes.
Add radius server <primary|secondary>
Description: This command configures the primary/secondary radius server for authentication.
Example: