3.8.7 RF Receiver Specifications
Table 3-7. Conductive Rx sensitivity-3GPP
Band
Items
Parameter
Unit
Min.
Typ.
Max.
L
T
E
B
a
n
d
2
5
M
Hz
wit
h 4
RB
s
99.5
LTE Band 4
RX Sensitivity
5 MHz with 4 RBs
dBm
101.5
LTE Band 12
RX Sensitivity
5 MHz with 4 RBs
dBm
98.5
Notes: 1. The RF receiver specification is defined at the LGA pad.
2. IMS2 fulfills 3GPP test standards.
3.9 Temperature
3GPP compliance: 20 °C to +60 °C (ambient)
Functional: 40 °C to +85 ° C
Storage: 40 °C to +85 ° C
3.10 LTE Power Saving Mode
Note: Details will be provided in a future revision of this document.
3.11 Serial Number and IMEI
Serial number and IMEI data can be written to the module only once; these two data