Options
This menu allows to change some parameters of the transmitter or display some information
Parameters
Range setting
Function
Name
ex.
TRANSMITTER1
To change the name of the transmitter shown in the
Status screen.
12 alphanumeric characters (A-Za-z0-9, case-sensitive)
DISPLAY brightness
0÷15 step 1
To set the brightness of the display
DISPLAY timeout
5÷60 step 5sec.
60÷120 step 10
sec.
To set the display timeout for:
decrease the brightness of the display and
return to Status screen
Info
IP address
ex.
192.168.10.1
to show the IP address
Serial
ex. R1825694
to show the serial number of the product
(the same indicated in the product label)
Option
ex. 0W2
To show the option
Range
ex. 470-800
to show the frequency range (MHz)
Temperatures
RF amplifier
ex. 30°C
to show the temperature took near the RF amplifier (°C)
RF generator
ex. 31°C
to show the temperature took near the RF generator (°C)
Micro
ex. 33°C
to show the temperature took near the RF
microprocessor (°C)
Power supply
ex. 31°C
to show the temperature took near the power supply (°C)
FW
FW ver
ex. 1.1
to show the firmware version (it sums up Boot+App+DSP
versions)
Boot ver
ex. 0.2.d
to show the bootloader version
App FW ver
ex. 0.36.d
to show the application firmware version
DSP FW ver
ex. 0.61.d
to show the DSP firmware version
Supply
diagnostic
Neg Audio (-12v5)
ex. -12.42V
To show the power supply of the input audio stages
Pos Audio (+12v5)
ex. 12.36V
To show the power supply of the output audio stages
RF conv. (+5v)
ex. 5.33V
To show the power supply of the RF converters
RF amplif. (+8v)
ex. 7.82V
To show the power supply of the RF amplifiers
MicroP. (+5v)
ex. 5.14V
To show the power supply of the microprocessor and the
digital section
Micro.P (+3v3)
ex. 3.41V
To show the power supply of the microprocessor and the
digital section
Main RAW (+12v)
ex. 12.62V
To show the main power supply
PLL tune (+22v)
ex. 23.29V
To show the power supply of the PLL
Alarms
ex. 0
To show the number “n” of active alarms:
n=0 0 active alarms
n>0 n active alarms
When “n”>0, it is possible to enter in the alarm submenu
which allows to show the alarms list: a brief description
and an alarm code for each alarm.
For the complete list of alarms, see Alarm List section
Note: the complete software and hardware status is displayed on the MTK952 info screen