Stereo Image Output Format
The two time-synchronized images from the two sensors of the oCamS-1MGN-U is multiplexed
frame-by-frame to be sent through one USB interface to a host system.
The image data from each image sensor is sent through 8 bits data bus and the multiplexed
image data from the two image sensors are sent through 16 bits data bus by the USB controller.
On the oCamS-1MGN-U, the 16 bit YUV2 format of the UVC (USB video device class) is used to
transmit the image data, and the host system will get the multiplexed image as shown below:
Picture 9. Multiplexed Image Received by a Host System
Without proper separation of the received image, a viewer will display the multiplexed image
shown below:
Picture 10. Non-separated Image Shown by a Viewer Program