Operation Manual

Occasional routines
10.2010 FB 7100 53
For a heavily soiled canister loosen the
retaining screw of the auger (fig. 56) and
carefully remove the dosing system.
Take care not to damage the
mixing wire.
Do not use a brush.
Clean the canister in hot water.
Dry the canister.
Assemble canister and dosing system.
Fill canister with freshbrew ingredient and
reinsert in machine.
Cleaning the dual chamber coffee
canister
A dual canister has two coffee chambers and
two dosing systems.
Each chamber and dosing system of the dual
chamber canister are disassembled and
cleaned in the same way as a canister with
one coffee chamber and one dosing system.
56