VERSION: 1.2 UPDATED: AUG 2013 WT‐1672A GSM Power Outage Alarm USER MANUAL WITURA TECHNOLOGY SDN BHD | WT‐1672A GSM Power Outage Alarm User Manual V1.
Overview Power Outage Alarm is a simple to detect loss of power (power cuts). Once power loss is detected, the unit will call and SMS to your cell phone via the mobile phone network to 5 designated phone number and/or sound an audible alert to make you aware of the power failure. The unit also has 1 x 30A heavy duty relay output can be used to switch on any application like lamps, pumps, heaters, motor etc when power outage.
SETTING UP AND PROGRAMMING When first booting up the system you will see Green LED Lights on the side of the Enclosure and it should light up when the Network is applied to the unit. The Green LED is the network Indicator and this will light up when attempting to log on to the network flash inconsistently until it locates the network. A Phone Call to the SIM Card Number will now Latch the Relay permanently ON and Switch the device being Controlled On.
Step 1 ‐ The simplest set up methods to set up Administrator number Applied the “KISS Principle”, keep it simple, stupid. The GSM Power Outage Alarm is easy to setup and use. Insert the SIM card, simply use your mobile phone call to the unit, your mobile phone number will automatically register as the 1st Administrators You will receive the following SMS message from the unit – Administrator: 1: 18617185299 (your phone number) 2: 3: 4: 5: You already finish the set up.
Factory Reset If you required to change the administrator number in the future, simply press the button “FACTORY” at the mother board until you hear the “du~” . This means the unit back to the factory default This means you already reset the unit to factory default. Now you can start to call again to set the administrator. This method of setting is only allowed to set 1 administrator number.
Step 2 ‐ Advance Set Up NO. Description 1 First Step of programming, you must enter the factory passwords of 1234 and go inside the programming mode. Programming Code *0*1234# SMS Texts Respond You get administrator privileges! 2013‐10‐09 00:33 Wed When you enter *0*1234#, you enter into the programming mode. You must perform the next command in 10 minutes. If you did not do anything, the system will exit from programming mode.
6 Check the relay status in ON or OFF Mode. *4* Master relay 2013‐10‐10 16:10 Thu 7 Check Signal Strength *5* CSQ<28> 2013‐10‐10 16:11 Thu The unit will return Master relay if the relay is on. The unit will return Master relay if the relay is off. You must confirm the signal strength at site before you install the unit. If the signal too weak, the unit will not function properly. CSQ 5 – 12 Signal too weak, system not function CSQ 13 ‐ 24 Signal Good.
10 Setting the year, month, day, hours, minutes, week *12*YYYYMMDDHHMMX# Time change OK! 2013‐10‐10 16:05 Thu YYYY=4 digit for Year MM = 2 digit for Month DD = 2 digit for Date HH = 2 digit for Hour MM = 2 digit for Minutes X = 1‐7 (Day of the Week) Example set as *12*2013101016054# which means 2013‐10‐10 16:05 Thu If reprogram the date, it will take the last as the accurate date.
14 SMS Reply Message when the system ON/OFF *21*N# Message switch 2013‐10‐10 17:06 Thu 15 To receive SMS Reply Message or not to receive SMS Reply Message when the system trigger by phone call *22*N# When sending command *22*0# Status switch 2013‐10‐10 17:10 Thu When sending command *22*1# Status switch 2013‐10‐10 17:08 Thu 16 Security mode/ Open Mode *23*N# When Setting as Security Mode *23*1# Mode switch 2013‐10‐10 17:13 Thu When Setting as Open Mode *23*0# Mode switch
17 SMS Text Message to Switch On/Off Relay *24*N# When Setting as *24*1# Master relay 2013‐10‐10 17:13 Thu N=1 means switch on the relay by SMS Message N=0 means switch off the relay by SMS Message When Setting as *24*0# Master relay 2013‐10‐10 17:13 Thu 18 Turn on / off the administrative call *25*N# 0 = Call Switch : 1 = Call Switch : Start Up Alarm 2 = Call Switch : AC down Alarm 0= turn off the call features , the units won’t make any call to administrative number 1 = when the d
Step 3 ‐ Installation Insert the SIM card, to access the SIM card carrier gently push the button adjacent to it, insert the SIM card and carefully close the carrier Connect the cable to terminals 110V ‐ 220V & N ensuring positive is connected to terminal 110v ‐ 200V, switch on the power supply , the red power LED will light indicating power is present, the blue network LED indicator will initially flash quickly, once logged onto the network , it will flash more slowly approximately one every 3 ‐4 seconds It
Connection Details If you are unsure how to connect the device you wish to control refer to a qualified person Connector Board Label Description Connection Details 1 2 3 4 J3 Relay NC No 5 6 Power Supply Power Supply 1 COM E N L Note 1. The Relay (J3 ) Was using for turning on and off the electrical appliance only 2. User can set up the Relay by own requirement 3.
Production Specifications Operation Voltage Operating Current Relay Contacts GSM Frequency MHz Humidity Operating Temperature Physical Size Weight Indicators Protection Approvals 110‐240 Vdc Maximum 500mA, typically 55mA 1 x Normally Open and Normally Closed Contacts maximum switching capacity 20 amps @230v ac per relay GSM 850, GSM 900, GSM 1800, GSM 1900 Less Than 80% RH ‐20c to 55c 130 x 100 x 50mm 500 Grams Relay , Telco , Power IP 65 Weather Proof Casing C.
Warranty Witura Technology Sdn Bhd warrantees the WT‐1672A GSM Temperature Alert and Monitoring System against defective parts and workmanship. Witura Technology Sdn Bhd shall, at its option, repair or replace the defective equipment upon the return of such equipment to any Witura branch.