WITURATECHNOLOGYSDNBHD|WT1672A GSMPowerOutageAlarm UserManualV1.813
ProductionSpecifications
OperationVoltage 110240Vdc
OperatingCurrent Maximum500mA,typically55mA
RelayContacts 1xNormallyOpenandNormallyClosedContacts
 maximumswitchingcapacity20amps@230vacperrelay
GSMFrequencyMHz GSM850,GSM900,GSM1800,GSM1900
Humidity LessThan80%RH
OperatingTemperature 20cto55c
PhysicalSize 130x100x50mm
Weight 500Grams
Indicators Relay,Telco,Power
Protection IP65WeatherProofCasing
Approvals C.E,FCC,ETSI
Troubleshooting
1. RedpowerLEDnotalight
Ensure that your DC power supply is connected
correctly,positive(+)toterminal220vandnegative()
to terminal N. Verify 12 volts is present using a volt
meter
2. BluenetworkLEDflashingeveryonesecond
andnotevery3seconds
Ensure yourSIM cardhasbeenactivatedandthatthe
PIN request has been disabled. If the unit is in a low
signal strength area consider using an external GSM
antennaorchangingtoanothernetworkprovider
3. Iamnotreceivingconfirmationtestmessages
whenprogramtheadministratorsnumber
Ensureyourtelephonenumberis intheAdministrator
list and that sendingtextmessages toyour number is
enabled.
4. Iamnotreceivinganytextmessageswhen
initiallyprogrammingtheunit
Ensure the unit is connect ed to the GSM network by
observing the blue network LED; it should be flashing
once every 3 seconds (see 2 above). Ensure the SIM
cardhascredit
5. Theunithasbeenworkingforseveralmonths
andhasnowstoppedrespondingtocallsand
textcommands
MostbutnotallPAYSIMcardswillbedeactivatedby
thenetworkifnotusedtomakeanoutgoingvoicecall
orsend an SMS text messagewithinaspecific
period.
To prevent this simply send a txt command *0*PW#,
then*2*, it willreply by textmessage, dothisoncea
monthtokeeptheSIMcardactive