Specifications

WITURATECHNOLOGYSDNBHD|WT1672A GSMPowerOutageAlarm UserManualV1.87
6 ChecktherelaystatusinONorOFF
Mode.
*4* Masterrelay<ON>
2013101016:10Thu
TheunitwillreturnMasterrelay
<ON>iftherelayison.
TheunitwillreturnMasterrelay
<OFF>iftherelayisoff.
7 CheckSignalStrength *5* CSQ<28>
2013101016:11Thu
You must confirm the signal
strength at site before you
installtheunit.
If the signal too weak, the unit
will not function properly.
CSQ 5 12 Signal too weak,
systemnotfunction
CSQ13‐24SignalGood.
System
functionwell
CSQ 25 32 Signal Excellent.
Systemworkingwell
8 ActivateorDeactivatetheAlarm
Function
*10*N# WhenSending*10*0#
Alarmswitch<OFF>
2013101016:28Thu
N=0(DeactivateAlarmFunction)
N=1(Activate Alarm Function)
Factory Default Setting as N=1
For example, if you want to
activate the alarm function just
enter*10*1#
When Deactivate Alarm
Function, is equal to
using the
Remote Control to disarm. The
D7GreenLEDlightinthesystem
will turn off. All the function
such as Outage Alarm,
TemperatureReport. When
deactivate alarm function, all
the alarm message will be
deactivate
When Activate Alarm Function,
is equal to using the Remote
Control to arm.
The D7 Green
LED light in the system will turn
on. All the function such as
Outage Alarm, Temperature
Report.
9
CheckingthestatusoftheAlarm
Functioninthesystem
*11* Alarmswitch<ON>
2013101016:29Thu
Checkthestatusofthealarm
functioninthesystem