User manual

11|Page
User Manual V2.6 Date: 12/6/2012
To check the SMS messaging matrix setting you would send the following SMS Message to the system.
Message sent *RER?#
Setting the Alarm Inputs
The system has 2 alarm inputs that will send SMS text alerts, activating the output relay or sound the siren
output when it triggered and these possible actions can be enabled or disabled independently.
The alarm inputs must be enabled in order to work. To enable the function of alarm input 1 you would send
the following SMS message to the system.
Message sent *CTR1#1
The visual screen will light up when this message has been received and if it is in the correct format you will
see a momentary indication that confirms it is correct and you will see the < OK > and will return a
confirmation SMS Message as
INCTR1=ON and Alarm Input one is enabled
To disable the function of alarm input 1 you would send the following SMS message to the system.
Message sent *CTR1#0
The visual screen will light up when this message has been received and if it is in the correct format you will
see a momentary indication that confirms it is correct and you will see the < OK > and will return a
confirmation SMS Message as
INCTR1=OFF and Alarm Input one is disabled
The same format is used for Alarm Input two using the *CTR2#1 or *CTR2#0 commands.
To check the settings of both alarm input you would send the following SMS message to the system.
Message sent *CTR?#
Setting the Possible Actions for Alarm Input
The alarm inputs can be programmed to send SMS text alerts, activating the output relay or sound the siren
output by enabling the possible actions when the alarm input has triggered.
To enable the possible actions for the alarm inputs you would send the following SMS message format to the
system.
SMS Command Format:
*CTC1#A,M1,M2,S
*CTC2#A,M1,M2,S