User manual
12|Page
User Manual V2.6 Date: 12/6/2012
Description:
A stands for the possible action (Selectable) 0 - 4
M1 stands for enable (1) / disable (0) sending of SMS alert *STR[N]#
M2 stands for enable (1) / disable (0) sending of SMS alert *STO[N]#
S stands for enable (1) / disable (0) sounding of audible siren
Selectable Possible Action (A):
Action 0:
- No Action
Action 1:
- Activates Output Relay 1 to stay on
Action 2:
- Activates Output Relay 2 to stay on
Action 3:
- Turn Off Output Relay 1
Action 4:
- Turn Off Output Relay 2
To program alarm input one to switch on output relay 1 and sends SMS text alerts only when
triggered you would send the following SMS Message to the system.
Message Sent *CTC1#1,1,0,0
The visual screen will light up when this message has been received and if it is in the correct format you will
see a momentary indication that confirms it is correct and you will see the < OK > and will return a
confirmation SMS Message as
CTC1=1,1,0,0 and the alarm input 1 has been programmed successfully
To program alarm input one to sends SMS text alerts and sound the siren output when triggered
you would send the following SMS Message to the system.
Message Sent *CTC2#0,1,0,1
The visual screen will light up when this message has been received and if it is in the correct format you will
see a momentary indication that confirms it is correct and you will see the < OK > and will return a
confirmation SMS Message as
CTC2=0,1,0,1 and the alarm input 2 has been programmed successfully