User manual

14|Page
User Manual V2.6 Date: 12/6/2012
STO2<Gate2 Closed!> and the input 1 restoral message has been programmed successfully
Input Trigger Delay Time Setting
The system will report the state of all inputs when any input changes state for longer than a
programmable trigger time. The trigger time of each alarm input is programmable and can be varied from
a minimum of 0.1 second to a maximum of 6553.5 seconds. Any change that does not remain stable for
the specified trigger time will be ignored. The factory default trigger time is 1 seconds.
To change the default setting of input one trigger delay time to 10 seconds you would send the
following SMS Message to the system
Message sent *DLY1#00100 and the command can be used up to a maximum of 65535 seconds with 5
digits from 00001 to 65535
The visual screen will light up when this message has been received and if is in the correct format you will
see a momentary indication that confirms it is correct and you will see the < OK > and the system will return
a confirmation SMS Message as
Message received DLY1=00100 and input one will alarm when it has triggered for 10 seconds.
Power down Alarm
The system has a built in function that will both send a SMS text alert and sound a siren output in the event
of a mains power failure at the gate and both these functions can be enabled or disabled independently.
To disable the Power down SMS text alerts for the power down function you would send the following SMS
message to the system.
Message sent *ALAC#0
The visual screen will light up when this message has been received and if it is in the correct format you will
see a momentary indication that confirms it is correct and you will see the < OK > and will return a
confirmation SMS Message as.
Message received ALAC-OFF and the power down SMS Messaging function has been disarmed
To enable this function again you would send the following SMS Messages to the system
Message Send *ALAC#1
The visual screen will light up when this message has been received and if it is in the correct format you will
see a momentary indication that confirms it is correct and you will see the < OK > and will return a
confirmation SMS Message as.
Message received ALAC-ON the power down SMS messaging function has been re-armed.