User manual

5|Page
User Manual V2.6 Date: 12/6/2012
same number in both admin 1 and admin 2 slot or even admin 3 can all be the same number of which the
system will call.
The system in this event will call number one and if it is not answered within the time scale set the system
will call the second number and then the third number before abandoning the attempt and logging off.
To check the administrator numbers in the list you would send the following command to unit.
Message Sent *ADM?#
The visual screen will light up when this message has been received and if is in the correct format you will
see a momentary indication that confirms it is correct and you will the < OK > and the system will return a
confirmation SMS Message as
Message received
TEL1
0124806804
TEL2
11111111111
TEL3
11111111111
END
Setting up the Caller ID System to activate security settings
The system will allow the 3 administrators automatic access to the system (Gates) via their Mobile Phone by
just calling the system which activates the output relay one as per the factory default of one second and to
set this function to the active mode you would sent the following SMS Messages to the system.
Message Sent *TEL?#1
The visual screen will light up when this message has been received and if is in the correct format you will
see a momentary indication that confirms it is correct and you will the < OK > and the system will return a
confirmation SMS Message as
Message received TEL-ON
Now if you call the system the Visual Display will show your telephone number and confirm you are an
ADMIN status and activate the relay one as per the default setting of one second.
Now the 3 Administrators can access the system direct via Mobile Phone as well as control the system when
called via the Intercom system.
Setting up the Guest list to be able to access the system
It is possible to allow up to 1000 user numbers to be stored that have access to the system via their Mobile
Phone or Land Line and these numbers can be entered or deleted remotely via SMS Messaging or using the
Soft Ware package provided.
For domestic applications where only a few numbers are to be added it is possibly easier and more
convenient to store them via SMS Messaging.