User manual
9|Page
User Manual V2.6 Date: 12/6/2012
Message Sent *EXT2#00360
The visual screen will light up when this message has been received and if is in the correct format you will
see a momentary indication that confirms it is correct and you will the < OK > and the system will return a
confirmation SMS Message as
Message received EXT2=00360 relay two will latch for 360 seconds when latched via the customer’s
handset when called using the
# prompt
Temporary latching the relays
It is possible to temporary latch both relays independently without affecting the default settings for a period
of from one second up to a maximum of 65535 and receive SMS Text alerts when the Relays have been
activated and also when they have returned to normal status in the Off mode, subject to the administrators
SMS alert being activated via the *RERN# command.
To Temporary latch relay one for say one hour 3600 seconds you would send the following SMS
Message to the system.
Message sent *RLY1#03600
The visual screen will light up when this message has been received and if is in the correct format you will
see a momentary indication that confirms it is correct and you will the < OK > and the system will show a
counter setting which will visually count down from the 03600 for Relay 1 and return a confirmation SMS
Message as
Message received RLY1=03600 and relay one is active for one hour or 3600 seconds
When the relay has completed the 3600 second cycle you will received a confirmation SMS Message as.
Message received RELY1-OFF and relay one is back to normal status as OFF
To Temporary latch relay two for say one minute or 60 seconds you would send the following
SMS Message to the system.
Message sent *RLY2#00060
The visual screen will light up when this message has been received and if is in the correct format you will
see a momentary indication that confirms it is correct and you will the < OK > and the system will show a
counter setting which will visually count down from the 00060 for Relay 2 and return a confirmation SMS
Message as
Message received RELAY2=00060 and relay one is active for one minute or 60 seconds
When the relay has completed the 60 second cycle you will received a confirmation SMS Message as.
Message received RELY2-OFF and relay two is back to normal status as OFF