WIZ-600Wi User Manual (Ver. 1.0) ©2007 WIZnet Inc. All Rights Reserved. For more information, visit our website at www.wiznet.co.
WIZ-600Wi User Manual WIZnet’s Online Technical Support If you have something to ask about WIZnet Products, Write down your question on Q&A Board in WIZnet website (www.wiznet.co.kr). WIZnet Engineer will give an answer as soon as possible. 2 Technical Support: support@wiznet.co.kr Sales & Distribution: sales@wiznet.co.kr For more information, visit our website at http://www.wiznet.co.kr © Copyright 2008 WIZnet Inc.
WIZ-600Wi User Manual Table of Contents 1. 2. 3. 4. Overview ....................................................................................................5 1.1. Main Functions ....................................................................................5 1.2. Specification .......................................................................................6 1.3. Products Contents (WIZ-600Wi-EVB) ...........................................................7 WIZ600Wi Module.........
WIZ-600Wi User Manual FIGURES Figure 1. Checking & Changing IP address of PC .................................................... 8 Figure 2. Searching Wireless Network ................................................................ 9 Figure 3. WIZ600Wi Log-in Screen ................................................................... 10 Figure 4. WIZ600Wi Log-in Completion Page....................................................... 11 Figure 5.
WIZ-600Wi User Manual 1. Overview WIZ-600Wi is 2.4GHz IEEE802.11b/g based wireless device that is used for embedded systems. WIZ-600Wi supports not only MII but also RS232C interface that enabling “Serial-to-Wireless” functions. By using WIZ-600Wi, embedded access point cab be implemented. 1.1. Main Functions Supports IEEE 802.
WIZ-600Wi User Manual 1.2. Specification < SOFTWARE > Item Operation mode Specification IEEE802.11b/g Access Point, Repeater, Client-bridge mode supported Radio Enable/Disable, SSID Hidden, Multi SSID, Auto Channel Select, Wireless 6 Rate Control (Include Auto mode), TX Power Control, Fragment Length, RTS/CTS Length, Short & Long Preamble, Super A/g Adaptive Radio, Beacon Interval, DTIM Period WPA, WPA2.0(with Radius Server or Pre-Shared Key), AES and/or TKIP, Security Unicast Encryption: 802.
WIZ-600Wi User Manual Sensitivity 1M: -94dBm, 54M: -68dBm Operating Range Indoor: 100 m, Outdoor: 400m Interface Ethernet 10/100 1 Port, UART, Factory Reset , Wireless Link/Activity LED, Ethernet Link LED, Two Antenna Port (Rx Diversity) Power DC3.3V (Pin header Type) Power (Internal) 3.3V, Temperature Storage: -20°C ~ +65°C Range Operating: -0°C ~ +55°C Humidity 10% ~ 90% (Non-Condensing) 2.85V, 1.8V 7 Table 1. Specification 1.3.
WIZ-600Wi User Manual 2. WIZ600Wi Module 2.1. Module Configuration 2.1.1. Connecting Web Browser WIZ-600Wi configuration can be processed though web browser. As default IP address of WIZ600Wi is ‘192.168.1.254’, the IP address of PC should be changed as ‘192.168.1.x’ for normal 8 connection. The default log-in information is & . The connection process is as below.
WIZ-600Wi User Manual STEP 3> In case of connecting through Ethernet, skip the step 3. When connecting through wireless LAN, connect to the network of which SSID is ‘wiznet’. 9 Figure 2. Searching Wireless Network © Copyright 2008 WIZnet Inc.
WIZ-600Wi User Manual STEP 4> After 1 minute later, input the address http://192.168.1.254 at the web browser. When connecting through wireless LAN, if connection is not normally processed, disable the wired network connection at the Control Panel, and try the connection again. 10 Figure 3. WIZ600Wi Log-in Screen STEP 5> If you input ‘admin’ in the Username and Password, you can go to the configuration page. The default value of both Username and Password is ‘admin’.
WIZ-600Wi User Manual STEP 6> If log-in is normally processed, below configuration page is appeared. 11 Figure 4. WIZ600Wi Log-in Completion Page 2.1.2. System Information and Network Configuration The configuration page of WIZ600Wi is composed of as below figure. The page can be divided into menu and its contents. The contents window is displayed according to selection of menu. Menu window is composed of System Information, Configuration and Firmware Upgrade. © Copyright 2008 WIZnet Inc.
WIZ-600Wi User Manual 12 s Figure 5. Configuration Tool – System Information and Network Configuration © Copyright 2008 WIZnet Inc.
WIZ-600Wi User Manual 2.1.3. System Info This is the menu to check WIZ600Wi’s information showing system and wired & wireless information. System Info System Info is selected, below information of WIZ600Wi can be checked. 13 à SYSTEM INFORMATION - AP Name: Displaying the name of AP - User Name : Displaying the ID of current user of AP - AP Version : Displaying the current version of AP à WIRELESS INFORMATION - AP Status : Displaying if AP mode is enabled or not. - SSID : Displaying current SSID.
WIZ-600Wi User Manual - RTS/CTS : Displaying the value of RTS/CTS. - Fragmentation : Displaying Fragmentation value. - Link Quality: Displaying wireless connection quality. - Signal level : Displaying current signal level. - Noise level : Displaying current noise level.
WIZ-600Wi User Manual à DHCP SERVER INFORMATION - Use DHCP Server : Displaying ‘Use DHCP Server’ is enabled or not - Start IP Address : Displaying ‘Start IP address’ assigned to DHCP server - Last IP Address : Displaying ‘Last IP address’ assigned to DHCP server - Subnet Mask : Displaying ‘Subnet Mask’ assigned to DHCP server - Refresh Time : Displaying refresh time of IP re-assignment 2.1.4. Client List If Client List menu is clicked, the station information connected to AP is displayed.
WIZ-600Wi User Manual 2.2. Configuration Menu You can change configuration value of all functions of WIZ600Wi. After completing the value change, re-start the system by clicking System Re-boot button. 16 Figure 6. Configuration Tool – Configuration Change © Copyright 2008 WIZnet Inc.
WIZ-600Wi User Manual 2.2.1. Wireless It configures wireless interface of AP. à RADIO CONTROL - AP MODE : Configure as Enable for Access Point à BASIC WIRELESS CONFIGURATION - Operation Mode Operation mode can be configured after wired connection is established. The connection can be closed at the wireless connection. z Access Point : WIZ600Wi operates as Access Point. z Station : WIZ600Wi operates as Station for the connection to another access point.
WIZ-600Wi User Manual à ADVANCED WIRELESS CONFIGURATION 18 - MAX User : It configures user number from 1 to 24. - Beacon interval : It is the transmission interval of Beacon. Beacon contains the information necessary for the communication including SSID. - DTIM Period : DTIM is used for Power Saving or Multicast/Broadcast. It can be configured in the range of 1~255. - Fragment Length : Fragment is the unit of packet segmentation. It can be configured in the range of 256 ~ 2346 Byte.
WIZ-600Wi User Manual 2.2.2. Network It configures internal network of AP. 19 Figure 7. Configuration Tool – Network à NAT CONFIGURATION - Use NAT : It configures ‘Use NAT’ is enabled or not. à NETWORK CONFIGURATION - Network Mode z DHCP : When using dynamic IP address, select the ‘DHCP’. As operating as AP DHCP Client, it acquires IP address from DHCP server connected to Internet line. z Static : When using fixed IP address, select the ‘Static’.
WIZ-600Wi User Manual - DNS Server 1 : The first DNS server address to be assigned to the server - DNS Server 2 : The second DNS server address to be assigned to the server 2.2.3. DHCP Server This page configure DHCP server and Relay function of AP. 20 Figure 8. Configuration Tool – DHCP Server à DHCP SERVER CONTROL : It selects if ‘DHCP MODE’ is enabled or not. -Start IP Address : It configures ‘Start IP address” to be assigned to DHCP.
WIZ-600Wi User Manual 2.2.4. Port Forward Port Forward operates only in case of using NAT. 21 Figure 9. Configuration Tool – Port Forward - Use Port-Forwarding : It selects use of ‘port forwarding’ function. - Port Number : Input port number to be used for port-forwarding - Protocol : It selects the protocol to be used (TCP/UDP, TCP, UDP). - Destination IP : Input destination IP address © Copyright 2008 WIZnet Inc.
WIZ-600Wi User Manual 2.2.5. Access Ctrl It configures AP access control. 22 Figure 10. Configuration Tool – Access Ctl à MAC ACCESS CONTROL It registers MAC address of Stations accessible to AP, and configures access allowance of the Stations. - - MAC Filter z Open : Allowing the connection from all MAC addresses z Allow : Allowing the connection from specified MAC addresses z Deny : Denying the connection from specified MAC addresses z Disable : Mac filter is not used.
WIZ-600Wi User Manual 2.2.6. Security It configures the security of connection to AP. 23 Figure 11. Configuration Tool – Security_WEP à WIRELESS SECURITY MODE - Security Mode : It selects WEP, WPA, or None(not used). à SECURITY CONFIGUATION - Authentication : It selects Open, Shared, or Auto Open : The authentication is not required between wireless networks.
WIZ-600Wi User Manual - WEP KEY : It uses WEP security. Users manually configure the value of key, Key Length and Key number. All values between AP and Station/Client are same, the communication can be processed.
WIZ-600Wi User Manual WPA-AUTO-PSK중 선택하여 지정합니다. - Cipher Type : It selects the type of WPA encryption - AUTO, WEP, TKIP, AES - Group Key Update Interval : Input interval value of Group Key update. The input range is 30 ~ 1800 seconds. If you input ‘0’, the update is not processed. - Pass Phrase Key : It configures PassPhrase. When using the character, 8~63 characters are used. If you use Hexadecimal, be sure to use 64 characters. - 802.
WIZ-600Wi User Manual 2.2.7. System Configuration 26 Figure 13. Configuration Tool – System à MANAGEMENT CONFIGURATION It configures use of Web Server and Telnet. à SNMP CONFIGURATION - Use SNMP : It configures use of SNMP function. - SNMP Manager IP : It configures IP address of SNMP management server. - Set community : It configures community value to save the SNMP MIB value of Access Point at the SNMP MIB browser. - SNMP Browser IP : It configures IP address of SNMP Browser server.
WIZ-600Wi User Manual à UART(RS232) CONFIGURATION - Use Serial Converter : It selects using RS232 data transmission mode or not. - Operation Mode : RS232 data transmission should be processed through server and client type. If one side operates as server, the other side does as client. - Server IP : When operated as Client mode, input server IP address. At the server mode, this value is ignored. - TCP Port : Input TCP port number for data transmission.
WIZ-600Wi User Manual 2.2.9. Firmware Upgrade 28 Figure 15. Configuration Tool – F/W Upgrade à TFTP Server - Firmware Version : It displays current firmware version. - File Name : Input file name of Firmware. - TFTP Server IP : Input TFTP server IP. - File Downloading : Download the file from TFTP server. * If there is the fail message of file downloading, check the file name and TFTP IP address. © Copyright 2008 WIZnet Inc.
WIZ-600Wi User Manual 2.2.10. Log It is used for checking log data of AP. Maximum 250 logs can be printed out, and max 500 logs can be saved. 29 Figure 16. Configuration Tool – Log - LOG Control : It configures log number to be printed out. © Copyright 2008 WIZnet Inc.
WIZ-600Wi User Manual 3. WIZ600Wi Hardware Specification 3.1. Usable Channel 3.1.1. Channel for 802.11b/g mode Channel NO.
WIZ-600Wi User Manual 3.2. Dimension ◙ Bottom View 31 ◙ Side View 7mm Shield can Heat sink Figure 17. WIZ600Wi Module Dimension © Copyright 2008 WIZnet Inc.
WIZ-600Wi User Manual 3.3. Connector BOTTOM Layer J2 : 2mm Pitch, Male, 1x5 32 J7 : 2mm Pitch, Male, 1x10 J10 : 2mm Pitch, Male, 1x5 J9 : 1.27x1.27, SMD, Male, 2x14 Figure 18. WIZ600Wi Connector Description No. Signal No. Signal 1 3.3V 2 3.3V 3 RXC 4 /RESET 5 TXD2 6 TXC 7 RXD1 8 TXD0 9 RXD0 10 TXD1 11 RXDV 12 TXD2 13 CRS 14 TXD3 15 RXERR 16 TXEN 17 MDC 18 COL 19 MDIO 20 GND 21 GND 22 PWFBOUT 23 RX+ 24 TX+ 25 RX- 26 TX- 27 GND 28 GND Table 5.
WIZ-600Wi User Manual 1 RX- 2 RX+ 3 TX- 4 TX+ 5 PWFBOUT 6 GND 7 GND 8 GPIO7 9 3.3V 10 3.3V Table 8. Pin Descriptions : Ethernet PHY Analog Signal& Wireless LED # GPIO2 : Ethernet Link (Active High) # GPIO6 : Factory Default (Active High) # GPIO7 : WLAN ACT (Active High) © Copyright 2008 WIZnet Inc.
WIZ-600Wi User Manual 4. WIZ600Wi Base board WIZ600Wi Base Board is the board for testing the WI600Wi module. It is composed of serial port, LAN port, reset switch and LED. 4.1. Description of base board WLAN_ACT Ethernet_LINK Factory_default 34 DB9 for USART (male) RJ45 for wired LAN (with transformer) Power Switch DC 5V Input Figure 19. WIZ600Wi Base Board z Ethernet_LINK : It is the LED to display the connection status of wired LAN.
WIZ-600Wi User Manual testing Serial-to-Ethernet function of the module. RJ45 : LAN cable is connected. It connects the PC or HUB to the module. Both of direct z and cross-over cable are used. z Power Switch : It is the switch for power ON/OFF. z DC 5V Input : It is connected to power adaptor. The power adaptor should be more than 1A standard. 4.2. Base Board Dimensions 13.00 67.00 75.00 78.60 1.00 8.20 35 Figure 20.
WIZ-600Wi User Manual 5. Serial Converter Operation Test Serial-to-Wireless function can be implemented by using ‘Serial Converter’ function. In this manual, the testing will be performed by using PC supporting wireless LAN and serial port. Device Terminal program is used for checking data communication. Device Terminal program can be downloadable at the WIZnet Homepage (http://www.wiznet.co.kr) 36 Figure 21.
WIZ-600Wi User Manual 37 Figure 22. Configuration Tool – Use Serial Converter STEP 4> Execute ‘Device Terminal’ program included in the CD. ‘Device Terminal’ is the combination program of serial terminal and network socket connection programs. It is developed for more convenient test of serial to Ethernet. Configure the IP address and serial baud rate according to the value of WIZ600Wi set in the STEP 3.
WIZ-600Wi User Manual 38 . Figure 23. Device Terminal Program - Configuration STEP 5> If connection is completed, perform the data transmission test. In order to test the data transmission from serial to Ethernet, input any data in the upper window of Device Terminal program. © Copyright 2008 WIZnet Inc.
WIZ-600Wi User Manual 39 Figure 24. Device Terminal Program – Input Serial Data STEP 6> If you click ‘Send’ button after inputting serial data, the data will be displayed in the lower window of the program as shown in
WIZ-600Wi User Manual ①Click ②Display received data Figure 25. Device Terminal Program – Send Serial Data Figure 26. Device Terminal Program – Input Network Data © Copyright 2008 WIZnet Inc.
WIZ-600Wi User Manual STEP 8> Click ‘Send’ button after inputting the data in the network terminal. If data is normally transmitted, received data is displayed in the upper serial terminal window. ②Display received data 41 ①Click Figure 27. Device Terminal Program – Send Network Data © Copyright 2008 WIZnet Inc.
WIZ-600Wi User Manual 6. Warranty WIZnet Co., Ltd offers the following limited warranties applicable only to the original purchaser. This offer is non-transferable. WIZnet warrants our products and its parts against defects in materials and workmanship under normal use for period of standard ONE(1) YEAR for the WIZ110SR board and labor warranty after the date of original retail purchase. During this period, WIZnet will repair or replace a defective products or part free of charge. Warranty Conditions: 1.