WIZ6000 User’s Manual (Version 0.9) ©2009 WIZnet Co., Inc. All Rights Reserved. ☞ For more information, visit our website at http://www.wiznet.co.kr WIZ6000 User’s Manual (WIZnet, Inc.
Document Revision History Date Revision 2009-09-09 V0.9 Changes Beta Release WIZ6000 User’s Manual (WIZnet, Inc.
Certification Information CE for Class B ITE INFORMATION TO THE USER Hereby, WIZnet. Declares that this WIZ6000 is in compliance with the essential requirements and other relevant provisions of directive 1999/5/EC. WARNING: This is a class B product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures.
WIZnet’s Online Technical Support If you have any questions about our products, please visit our website and submit your questions on the Q&A Board. We will reply your questions as soon as possible CLICK COPYRIGHT NOTICE Copyright 2009 WIZnet, Inc. All Rights Reserved. Technical Support: support@wiznet.co.kr Sales & Distribution: sales@wiznet.co.kr For more information, visit our website at http://www.wiznet.co.kr WIZ6000 User’s Manual (WIZnet, Inc.
Contents 1. Introduction ........................................................................................................................ 1 1.1 Products Contents ............................................................................................. 2 1.2 Product Specification ......................................................................................... 3 1.2.1 WIZ6000 Device Server Interface ..................................................................... 5 2.
Figures FIGURE 1. WIZ6000 DEVICE SERVER INTERFACE ............................................................................. 5 FIGURE 2. CONNECTING TO THE WEB PAGE OF WIZ6000 .................................................................. 6 FIGURE 3. INPUT ID AND PASSWORD .................................................................................................7 FIGURE 4. SYSTEM DATA ................................................................................................................
Tables TABLE 1. PRODUCTS CONTENTS. ......................................................................................................2 TABLE 2. PRODUCTS SPECIFICATION – WIRELESS ............................................................................. 3 TABLE 3. PRODUCTS SPECIFICATION - SOFTWARE ............................................................................. 3 TABLE 4. PRODUCTS SPECIFICATION - HARDWARE ..........................................................................
1. Introduction WIZ6000 is t he external g ate way mod ule whi ch p rovides a b ridge for RS -232 or Ethernet to IEEE802.11 b/g wirel ess communications. Device s with the interface of RS -232C serial or Ethernet can established a wireless network which can enable remote monitoring, management and controlling. Main Features Embedded 802.
1.1 Products Contents WIZ6000 Device Server Included Dipole Antenna (3.377dBi SMA Type) Serial Cable Network Cable (Crossover Cable) Power (DC 5V / 2A Adaptor) Data CD (Manual, H/W & SW related Materials) Table 1. Products Contents. WIZ6000 User’s Manual (WIZnet, Inc.
1.2 Product Specification Wireless ITEM Specification Wireless Standard IEEE802.11b/g Frequency Range 2.412~2.485GHz Output Power 802.11b: 16dBm@11Mbps (Max 10mW / 1MHz) (Tolerance(+/-2dBm) Receive Sensitivity Data Rates 802.11g: 14dBm@6~54Mbps (Max 10mW / 1MHz) 802.11b: -65dBm@11Mbps 802.11g: -76dBm@54Mbps 54Mbps-1Mbps 11g: OFDM(64QAM, 16QAM, QPSK, BPSK) Modulation Type 11b: DSS(CCK, DQPSK, DBPSK) Table 2.
Hardware ITEM Specification Ethernet 1 Port, RS-232C 1 Port, DC 5V Power input Interface 3.377dBi SMA type Dipole Antenna Operation: -5℃~55℃ Temperature Storage: -20℃~70℃ Operation: 10% to 90%, Non-Condensing Humidity Storage: 5% to 90%, Non-Condensing Baud Rate : 230,400bps Stop bits: 1 Serial Parity: None, Odd, Even (RS-232C) Flow Control: XON / XOFF (Software), CTS / RTS (Hardware), None Power DC 5V input Power Consumption Dimension Under 600mA ( 3.3V ) 90.5mm X 94.5mm X 22.
1.2.1 WIZ6000 Device Server Interface Figure 1. WIZ6000 Device Server Interface WIZ6000 User’s Manual (WIZnet, Inc.
2. Getting Started This manual describes all configurations in detail. For the quick and easy installation, please refer to “ WIZ610wi Quick Installation Guide”. 2.1 Hardware Installation STEP1: Connect the WIZ6000 to the HUB or PC by using a network cable. STEP2: Connect the WIZ6000 to the serial device by using the RS-232C serial cable. STEP3: Insert the power supply co nnector to the WIZ6000 by using the 5V / 2A DC power adaptor.
Figure 3. Input ID and Password 2.2.2 Checking Status 1) System Data Figure 4. System Data WIZ6000 User’s Manual (WIZnet, Inc.
ITEM Description Firmware Version The firmware version of WIZ6000 is displayed Firmware Date The last date and time of firmware upgrade MAC Address(LAN) The MAC Address of WIZ6000 for Ethernet communication. IP Address The IP address of WIZ6000. Network Mask The Network Mask of WIZ6000. Default Gateway The Gateway of WIZ6000. DHCP Server Shows the DHCP server function is activated or not. DHCP Start IP Address Shows the first IP address to be assigned from DHCP server.
2.2.3 Network Setting You can configure network parameters of WIZ6000 Figure 6. Network Setting IP Address: The default IP Address is set as “192.168.1.254”. Subnet Mask: The default Subnet Mask is set as “255.255.255.0”. Default Gateway: The default Gateway is set as “0.0.0.0”. DHCP: If you want to activate the DHCP Server function, select the “Server”. If not, select “Disable”.
Figure 7. Active DHCP Client Table 2.2.4 Wireless Setting 2.2.4.1 Mode Selection You can select one of Access Point, Gateway and Client for the wireless connection mode. Figure 8. Operation Mode Access Point is the default mode. If you select Gateway or Client and click the “Setup” button, the progress bar will be shown. WIZ6000 User’s Manual (WIZnet, Inc.
Figure 9. Changing Operation Mode 1)Access Point Mode In this mode, all Ethernet port s and wireless interface are bridged together and NAT function is disabled. All the WAN related function and firewall are not supported. 2)Gateway Mode In this m ode, your d evice can conn ect to the inte rnet via ADS L/Cable Mo dem. The NAT is enabled and PCs in LAN ports share the same IP to ISP through WAN port. WAN connection type can be setup in WAN page by using PPPOE, DHCP client, PPTP client or static IP.
2.2.4.2 IP Configuration in Each Mode 1) Access Point Mode Figure 10. Access Point Mode - 1 - The IP address assigned to WIZ6000 is for administration and web configuration. - Even though the WIZ6000 is configured as DHCP Server, the PC will acquire IP address from IP Sharing device or ADSL/Cable Modem. Figure 11. Access Point Mode -2 - If there is not IP Sharing Device or ADSL/Cable modem, WIZ6000 will assign the IP addresses which is in DHCP IP range to PCs through wired or wireless network.
2) Gateway Mode Figure 12. Gateway Mode - WIZ6000 operates as DHCP Server for the wireless communication. - WIZ6000 operates as Static/DHCP/Client/PPPoE for the wired (Ethernet) communication. 3) Client Mode Figure 13. Client Mode - WIZ6000 can be set IP as Static or DHCP client at ‘Client Setup>WAN Port Setup’. And al so WIZ6000 can b e act DHCP Server simultaneously by assigning a dding 1 00 of fi rst DHCP server . For exam ple, if DHCP server ’s cl ient r ange is XXX.XXX.XXX.
2.2.4.3 Access Point Setup After selecting the AP mode and please click “Setup” button, the page below is shown. Figure 14. AP Mode Settings Alias Name : Input the name for WIZ6000. Band : Select communication protocol of WIZ6000. Notice 802.11g protocol is compatible with 802.11b. SSID: Input SSID for wireless communication. All devices o n the same wireless net work should h ave same S SID. The SSID ca n have max 32bytes characters composed of alphabets and numbers.
Mode : Select mode - AP : IF AP is selected, WIZ6000 operates as Access Point. - WDS Repeater : WDS (Wireless Distribution System) that can be used for the communication between WIZ6000 and WIZ6000. When this mode is selected, AP function operates at the same time. Security : Configure the security options for WIZ610wi. When you click “Setup” button, below page appears. Figure 15. Wireless Security Setup Authentication You can select an authentication method for the clients to connect to AP.
WPA PSK WPA Pre-Shared-Key is the authentication method using Pre-Shared Key. Configure PSK format and input value for PSK. WPA2 RADIUS WPA2 is using AES(Advanced Encryption Shared) algorithm. AES is more strengthened encryption method rather than RC4 which is used for WEP or WPA. WPA2 RADIUS performs AES encryption and RADIUS server authentication. If WIZ610wi uses WPA2, it can be compatible with devices using WPA1.
Advanced Settings : If you click the “Setup” button, below page is appeared. Figure 16. Wireless Advanced Settings Field Description Fragment This value specifies the maximum size for a packet before data is Threshold fragmented into multiple packets. If you experience a high packet error rate, you may slightly increase the Fragmentation Threshold. Setting the Fragmentation Threshold too low may result in poor network performance. Only minor reduction of the default value is recommended.
Preamble Type Beacon Interval The default value is 100. Enter a value between 1 and 65,535 milliseconds. The Beacon Interval value indicates the frequency interval of the beacon. A beacon is a packet broadcast by the Router to synchronize the wireless network. Table 8. Wireless Advanced Settings Access Control By registering the MA C address of a client, WIZ6000 blocks or allows the client to acce ss. If you click the “Setup” button, page below appears. Figure 17.
Figure 18. WDS Setting Input wireless MAC address of the device to be connected. Apply Changes: Add the MAC address into the WDS list Reset: Discard all changes in all fields. 2.2.4.4 Gateway Setup Notice When cha nged to Gateway mode, wired netwo rk is disco nnected, It becau se WIZ6000’s wire port act as WAN Port. So to solve this problem.. 1. Connect WIZ6000 through wireless 2. Check WAN IP of Gateway mode setup page 3.
Figure 19. Gateway Setup Alias Name: Refer to “2.2.4.3 Access Point Setup”. Band: Refer to “2.2.4.3 Access Point Setup”. SSID: Refer to “2.2.4.3 Access Point Setup”. Channel Number: Refer to “2.2.4.3 Access Point Setup”. Security: Refer to “2.2.4.3 Access Point Setup”. Advanced Settings: Refer to “2.2.4.3 Access Point Setup”. Access Control: Refer to “2.2.4.3 Access Point Setup”. WAN Port : If configures WAN port. It configures the network environment for the connection to WIZ6000.
Figure 20. WAN Port Configuration WAN Access Type - Static IP : Manually input your IP address, Subnet Mask, Default Gateway and DNS. - DHCP Client : An IP address can be acquired from a DHCP server. The DNS information can be automatically acquired from a DHCP server or set manually (Set DNS Manually).. WIZ6000 User’s Manual (WIZnet, Inc.
PPTP - Virtual Server: Virtual Server also known as Port Forwarding associates a port number with a private IP address(internal network). This technique allows clients from outside a network to access devices within the LAN (internal network). - DMZ: This feature allows one network user to be exposed to the Internet for specialpurposes such as Internet gaming or videoconferencing. DMZ hosting forwards all the ports at the same time to one PC.
2.2.4.5 Client Setup In client mode, WIZ610wi connects to an access point. Figure 22. Client Setup Alias Name: Input the name for WIZ6000. Band: Select a commu nication protocol for your mod ule. It suppo rts 802.11b, 802.11g and 802.11b/g mode. SSID: Input the SSID of a n access poi nt. If y ou do n’t know you r SSID, you can u se the “Site Survey” to search and connect to an AP.
Figure 23. Site Survey 2.2.5 Serial Setting For the ‘Serial to Wireless’ communication, you can configure serial parameters. Figure 24. Serial to Ethernet Configuration WIZ6000 User’s Manual (WIZnet, Inc.
Status: Check this combo box to enable serial communication Mode: Select one mode among Server, Client and Mixed. This mode is to select the communication method based on TCP. TCP is the protocol which establishes the connection before data communication. In server mode, WIZ6000 waits for the connection from a clie nt. In client mode, WIZ60 00 operates as client at the TCP Client mode on the process of connection, and tries to connect to the server ’s IP and Port.
Server IP : Input server IP. Server Port : Input server port. Reconnect Interval: Set the interval retrying connecting to server. Baud rate: Configure serial communication speed. Data bits: Configure data bits. Parity: Configure parity checking option. (option: None, Odd, Even) Stop bits: Configure stop bit option.(Option: 1, 2) Flow Control: Configure flow control option. (option: none, Xon/Xoff, RTS/CTS) Save : Save the configuration values.
2.2.6 Security Setup Refer to “2.2.4.3. Access Point Setup’. 2.2.7 Others 2.2.7.1 Password You can change the password of WIZ6000 Figure 25. Password Setup 2.2.7.2 Log The log information can b e saved. In o rder to use this functio n, check the combo box “Enabl e Log”. The log will include information such as wireless, DDNS, WAN and DHCP. Figure 26. System Log WIZ6000 User’s Manual (WIZnet, Inc.
2.2.7.3 Upgrade In this page, you can upgrade the firmware of your WIZ6000. Browse the firmware file b y clicking the “Find” button. If you click “Upload” button after selecting firmware file, the firmware starts uploading. This process will take about 60 seconds. Figure 27. Upgrade Firmware 2.2.7.4 Factory Default If you click the “Fa ctory Default” b utton, all se ttings value are resto red to the factory de fault setting. The factory default values are shown below: Field Default Value IP Address 192.
Wireless Mode AP Alias Name Wireless_AP Band 2.4GHz (B +G) SSID WIZ61 0wi Channel 1 AP Mode AP Authentication Open system or Shared Key Encryption N one Fragment Threshold 2346 RTS Threshold 2346 Preamble Type Long Preamble Beacon Interval 100ms Inactivity Time 30000ms Broadcast SSID Enable WMM Enable Password Admin Log Disable Table 9. Factory Default Value 2.2.7.5 Reboot In this page, you can reboot your module Figure 28. Reboot System WIZ6000 User’s Manual (WIZnet, Inc.
3. Hardware Specification 3.1 WIZ6000 Dimension A 90.5 B 67.5 C 11.5 D 14.5 E 26.0 F 27.0 G 5.2 H 6.3 I 4.5 J 7.0 K 22.5 L 9.0 M 8.0 N 11.5 O 16.5 P 9.0 Q 22.5 R 87.5 S 94.5 Figure 29. WIZ6000 Dimensions (unit : mm) WIZ6000 User’s Manual (WIZnet, Inc.
3.2 Connector Specification 3.2.1 RJ-45 Connector Ethernet port Pin outs Pin Signal 1 TX+ 2 TX3 RX+ 6 RXFigure 30. RJ-45 PIN Assignment 3.2.
4. Demonstration and Test In this ch apter, an exam ple is provided f or you to test the function ality of WIZ6000. The te sting environments are the followings: A PC equipped with a RS-232 serial port WIZ6000 Device Server Connect PC and module’s Ethernet port by using an Ethernet Cable (Direct or Crossover) Connect PC and module’s serial port by using a serial cable Hyper Terminal (or any other terminal program) Step 1.
③ Connect to “WIZ6000” in the Wireless Network Setting of your PC Figure 32. Wireless Network Connection ④ Execute one more terminal program, and set IP address and Port number. Figure 33. Network Terminal Program configuration ⑤ Input any chara cters i n the Hype r T erminal f or Seri al. (I n the exam ple belo w, “01234567890” is input). The same characters are outputted in the Hyper Terminal for Network. A Serial to Wireless LAN test was performed.
Figure 34. Received Data by Network Terminal Program Figure 35. Serial to Wireless LAN 구성 ⑥ In the same way, input an y characte r a t t he screen of terminal p rogram for ne twork, and check if same character is displayed at the screen for serial. ( Ethernet to Serial ) WIZ6000 User’s Manual (WIZnet, Inc.
※ The above test can also be performed in a program called, “Device Terminal program”, which is easy and simple to use. Figure 36. Device Terminal Program Device Terminal is a program which integrates both serial and network communications into one user interface so that you can test your WIZnet gateway module easily. As sho wn in above Figu re, the upper p art of the program allo ws you to config ure your serial setting of WIZ6000. By clicking the “Open” button, serial communication is enabled.
5. Serial Configuration Serial Command Format It is possible to configure WIZ6000 by using serial command. RS-232C port’s Pin number 1 of WIZ6000 is Hardware trigger pin. ( ‘1’: H/W trigger disable, ‘0’: enable ) < Frame Format > Command Frame format Descriptor STX Command code Parameter ETX 2 Variable 1 Length(bytes) 1 Table 11. Serial Configuration Frame format Reply Frame format Descriptor STX Reply code Parameter ETX 1 Variable 1 Length(bytes) 1 Table 12.
2 Invalid parameter 3 Invalid ETX E Enter Serial Command Mode Table 14. Serial Configuration Reply Code Command Code Com Get/ mand Set Comments Parameter Time Network Firmware RF Get Version vx.x.x 1 0:Ethernet MAC address, 1:Wireless MAC address, RA Get MAC Address RI Get IP Address 1 WI Set IP Address 2 RS Get Subnet Mask 1 WS Set Subnet Mask 2 RG Get Gateway
<1:xxx.xxx.xxx.xxx[_xx.xx.xx.xx]> or<0> RV Get DNS Server 1:Enable, 0:Disable_DNS Server IP address 1 or<0> 0:Static, 1:DHCP Client, 2:PPPoE, 3:PPTP -Static: 0_Ipaddress_Subnet_Gateway_DNS -DHCP Client: 1_IPaddress_Subnet_Gateway RT Get WAN Port
Mode DS Get SSID GS Set SSID DC Get Channel GC Set Channel 1~32 chars 1 1~32 chars 1 Auto_0, 1~13 1 Auto_0, 1~13 2 1:Master,2:Slave DW Get WDS _count_MACaddress_Comment[_MACaddress_Comment_...] 1 1:Master, 2:Slave_1:add, GW Set WDS 2:delete_count_MACaddress_Comment[_MACaddress_ Comment_..
DI Get Site Survey DN Get Alias Name GN Set Alias Name QP Get SSID_BSSID_Channel_RSSI_Security 15 Alias Name 1 Alias Name, Max Length: 29bytes 1 Module connection status_SSID_BSSID_CHAN_RATE_RSSI Status Conn_status: ‘0’ is not connected, ‘1’ is connected.
WK Set Protocol RM Get Mode WM Set Mode RX Get Server IP WX Set Server IP RP Get Port WP Set Port TCP_0, UDP_1 1 0:Client, 1:Mixed, 2:Server 2 0:Client, 1:Mixed, 2:Server 1 Server IP address 1 Server IP address 2 0~65535 1 0~65535 1 eg.
OS Set Size QC Get Char OC Set Char QI Get OI Set 00~ff 00~ff 1 Time Inactivity 00~60 Time :Client) 1 00~60 Status(Server 1 Inactivity Connection RC Get 0~255 1 1 0: Not Connect, 1:Connect 1 Others WF Set WR Set error code Factory Default Restart 55 55 S or Commend is successfully applied F Failed to apply 0 <0> "<" is wrong 1 <1> There is not in command list 2 <2> Wrong Parameter factor 3 <3>
If input "_" in fact, should input"__" instead of "_". For example SSID, PSK etc. --> : SSID: 11_22 --> : SSID: 11_22 --> : SSID: 11_22 If multi command input, response time be delayed For example DA, GA, DW, GW Notice Security Available mode AP/GW Mode AuthMode: 0-7 EncryptTyp e: 0-3 Client Mode AuthMode: 1,3,5,7 EncryptTyp e: 0,1,4 **Security Example parameter
6. Warranty WIZnet Co., Ltd offers the following limited warranties applicable only to the o riginal purchaser. This offer is non-transferable. WIZnet warrants our products and its parts against defects in materials and workmanship under normal use for period of standard ONE(1) YEAR for the WIZ6000 board and labor warranty after the date of original ret ail purchase. Duri ng this pe riod, WIZnet will repair or repl ace a defective products or part free of charge. Warranty Conditions: 1.