1.6.7.2.3.3 Class0 Plus INIT Subcommand (02
h
)
Performs a Class 0 Plus (Impinj/ZUMA) INIT command. If a filter is supplied, tags are first singulated
then processed. If no filter is supplied, the global mode is used for processing.
Request Packet
Opcode
0x18
Command Data
Antenna
1 byte
0x00: Ant A
0x01: Ant B
RF Power Level
1 byte
0x01 (min) – 0xFF (max)
Singulation
(Negotiation
Page) Field
1 byte
0x00 (ID0)
0x01 (ID1)
0x02 (ID2)
Subcommand
1 byte
0x02
Lock Flag
1 byte
0x00 (Do Not Lock)
0x01 (Lock)
Filter Bit Count
1 byte
0-64 or 0-96
Filter Bits
0-12 bytes
Tag ID filter bits are left justified in bytes, MSByte is sent first
Note: Any tag that processes this command MUST then complete a power cycle.
Note: Singulation Fields ID0 & ID1 are not implemented yet.
Response Packet
Status
0x00 (Complete)
Total Tags reported
2 bytes
Under-run error count
2 bytes
Tag CRC error count
2 bytes