Operation Manual
94
User Manual WMF1500S
Appendix: Technical data
Mains voltage
tolerance range
230V +6 % and –10 %.
Mains voltage interruption < 50ms: no interruption of
function
Water supply 3/8inch hose connector with mains tap, and filter with
0.2to 0.25mm mesh size, on site.
At least 0.2MPa (2bar) flow pressure at 2l/min
(standard). Maximum 0.6MPa (6bar).
Maximum inlet temperature 35°C.
The set of hoses provided with the new coffee machine
and/or the new water filter must be used. Do not use old
hoses.
Water quality For drinking water with carbonate hardness above
5°dKH, aWMFwater filter should be fitted upstream.
Water drain tube
(optional)
Tube aminimum of DN 19, minimum downward slope of
2cm/m
Ambient temperature +5°C to +35°C
(empty the water system in case of frost).
Maximum humidity 80 % relative humidity without condensation.
Do not use device outdoors.
Degree of protection IP X0
Installation
surface/water spray
The device must be placed and leveled on ahorizontal,
sturdy, water-resistant, and heatproof base.
The device must not be cleaned using awater jet. The
device must be installed where it is protected against
water spray. The device must not located on asurface
that is sprayed or cleaned with awater hose, steam jets,
steam cleaner, or similar devices.