Operation Manual
95
User Manual WMF1500S
Appendix: Technical data
Installation clearances
For operating, service, and safety reasons the
machine should be installed with aclearance of not
less than 50mm at the sides from the building or
non-WMFcomponents.
A minimum working space of 800mm in front of the
coffee machine is recommended. Aclear height of
1,100mm from the top of the supporting surface should
be ensured. The height of the installation surface above
the floor is at least 850mm. If the coffee machine
connections are to be run downwards through the
counter, please make space for the lines, which can
reduce the usable space below the machine.
Installation dimensions
of the water filter
See the User Manual for the water filter.
These specifications for the electrical connection and the standards quoted
apply for connecting the coffee machine in EU countries. It may be necessary
to also observe additional country-specific regulations. Outside the EU
countries acceptance of the standards quoted is to be checked by the legal
entity or natural person who wishes to use the coffee machine.
The local power supply must be constructed according to IEC 364 (DIN VDE 0100).
To improve safety, the device should be fitted with an FI 30mA earth leakage
current circuit breaker complying with EN 61008. (Type Bresidual current circuit
breakers provide reliable tripping even if the fault current is smooth. This ensures
ahigh level of safety.) Near the device or about 30cm below the counter top there
should be ashockproof socket as asingle-phase connection installed locally on
the rear or side wall of the counter substructure or acountry-specific single-phase
socket. The mains switch and plug top are part of the on-site installation. The
mains cable must not come into contact with hot surfaces. If the mains cable
for this device is damaged then it must be replaced by our service personnel
or asimilarly qualified person, in order to prevent hazards. The coffee machine
may not be fitted with afixed permanent mains connection if installed on
atransporting trolley (a mobile station).
In order to avoid possible faults from arising on our shielded data lines due to
potential equalisation currents between the devices, an additional potential
equalisation unit should be planned for devices connected to the vending system.
(See EN 60309)