User manual

ALM26 Series User Manual P/N 821644 Rev-A
12
© 2006 Wohler Technologies Inc. ALL rights reserved
B
Please refer to Figure-2b on the following page to familiarize yourself with the rear panel features of the ALM26 Series units
covered by this manual. The following sections describe these features and are referenced, by letter, to Figure-2b.
Rear Panel Features
Section 2: Operation
(Continued)
A
A1
A2
Digital (AES) Audio Inputs
(ALM26-nnD Only)
Each input connector receives an AES digital signal from which two channels are derived.
Phoenix Connectors (Standard)
These Phoenix (or XLR) connectors are configured for a balanced (110 impedance) connection. Channel numbers are
displayed on a label to the side of each connector and correspond to the channel numbers above the associated LED
indicators on the front panel. Connector pinout information is silk-screened just below each connector.
BNC Connectors (Optional)
These BNC connectors are configured for an unbalanced (75 impedance) connection. Channel numbers displayed
on a label above or below each connector and correspond to the channel numbers above the associated LED indicators
on the front panel.
Digital AES Termination, Reference Level, and Display Mode DIP Switch
(ALM26-nnD Only)
This DIP switch sets the Termination for the input connectors, and the bargraph Display Mode and Reference Level for the
associated bargraph displays. Each DIP switch module affects only the four channels (two input connectors) within the
section in which it is located. See the descriptions and diagram below for setting information.
Termination:
Switch sections 1 (left connector) and 6 (right connector) respectively set the termination for the connector inputs in each 4-
channel input section. The respective DIP switch section should be moved to the UP position to UNTERMINATE the
connector if the input signal is fed to downstream equipment. The respective DIP switch section should be moved to the
DOWN position to TERMINATE the connector if the input signal is not fed to downstream equipment. The factory default
setting is TERMINATED for each input connector. See diagam below for settings.
Reference Level:
DIP switch sections 2 and 3 determine the Reference Level, which adjusts the level of the input signal and the resultant level
displayed on the LED bargraphs. Factory setting is -20 dBfs. See diagam below for settings.
Bargraph Display Modes:
DIP switch sections 4 and 5 determine how peak levels are displayed for the four associated meters on the front panel. There
are four possible settings; VU Bargraph Only, VU Bargraph with PPM Floating Segment, PPM Bargraph Only, and
PPM Bargraph with PPM Floating Segment. The factory default setting is VU Bargraph with PPM Floating Segment.
See diagam below for settings. See the ALM26 Internal Settings - Address, Peak Hold, PPM Characteristics diagram
on page 23 for how to set the Peak Hold and PPM Ballistics characteristics.