Rear Panel Features
Section 2: Operation
(Continued)
E
F
G
H
Option Select Switch
This 10-position BCD (Binary Coded Decimal) rotary switch is used to set operation of the unit. It can be accessed using
a small flathead screwdriver or similar tool. See table below for settings.
Please note that choosing alternate scales may require a change to the scale indication silk-screening next to the bargraph
display level meters on the front panel. See page 24 (Level Meter Alternative Scales) for more information.
Port 1 Connector
This DB-25 connector (Port 1) is used to convey alarm conditions
to outboard equipment. This port has isolated contact closures,
which indicate Alarm conditions for the associated channel or
channel pair. These contacts are normally open and close on
alarm.
In units with twelve or fewer channels, each relay represents a
single channel. In units with more than twelve channels, each
relay represents a pair of channels.
A summary contact pair exists between pins 1 and 14. If any
relay pair in the unit closes, the summary contacts also close.
Example: If channel 15 or 16 trips into alarm, a contact closure
will occur between pins 9 and 21 and between pins 1 and 14 for
the duration of the alarm.
See the table to the right for connector pinout details.
NOTE: An option is available to make the relay operation
independent of the alarm indications and resets. Contact the
factory for details and instructions on enabling this option.
Power Input Connector
Attach a standard IEC-320 power cord between this connector and mains power (100 - 240VAC nominal, 50/60 Hz). The
front panel Power Indication LED (Item 5, page 10) will glow GREEN to indicate operating voltages are present.
Serial Control Connector
This connector is used for Remote Control and for software upgrades of the product. See table below for pinout information.