User guide
821116: AMP2 -1 6 V S e r i e s U se r Guide
© 2 0 14 Wohler Te c h no l o g i e s, Inc. All rights re se r ved..
173
Ch apt er 8 Troubleshooting
No rmal Messages
Inconsistent Module List
If you recently removed any of the I/O cards from the AMP2-16V
Series monitor, you will see the following message.
Figure 8–2 Message: Removed Module?
If you have not recently removed an I/O module, remove the top cover
to verify that all the cards are seated properly, then restart the unit.
Restart
When powering up the AMP2-16V Series monitor, you may see the
following message.
Figure 8–3 Message: Restart
Serial
Port
Initialize
Did you add or remove an optional module?
The system module list has changed. This is normal if you recently added
or removed a module. Press Initialize to set all presets to defaults and to
update the module list, or press Serial Port to enable serial port and
Ethernet access.
Slot: Expected Detected
PS1: 8AES Input Board 8 AES Input Board
PS2: 3G SDI Input Board 3G SDI Input Board
PS3: 3G SDI I/O Board 3G SDI I/O Board
PS4: 8 AES Output Board 8 AES Output Board
PS5: 8 In/8 Out analog Board 8 In/8 Out Analog board
Dolby: Installed Not Installed
Restart
System restart in process… Please wait.