User guide

821116: AMP2 -1 6 V S e r i e s U se r Guide
© 2 014 Wo h l e r Te c h n o l o g ies , In c. A l l r ights re se rve d.
32
Chap ter 3 T he H ow Do I .. . Chap te r
Frequently Aske d Q ue stions
Figure 3–5 Loudness Measurement Menu
1. Use the Loudness Standard knob to set the standard you need.
2. Use the Mode knob to set whether you want loudness calculated
continuously or manually, using start/stop buttons.
3. Refer to Loudness Measurement Menu on page 117 for complete
information on setting up all of the adjustments available in this
menu.
How Do I Set Up for External Surround Sound?
If a studio or other monitoring environment contains a surround sound
system, it may be advantageous to connect the monitored sound from
the AMP2-16V Series monitor to this system. Up to four pairs (eight
Save / ExitHelp Cancel
Loudness
Clusters
Loudness
Standard
EBU R128 (+9 Scale)
Loudness Measurement Menu
Reference
Level
LRA
Window
-23.0 LKFS
9 Seconds
+/- 1 LU
Alarm
Tolerance
ContinuousManual
Mode
OffOver
Alarm
BothUnder
Momentary
Short Term
Custom: 3 Sec
Loudness
Window
Important:
In order to calculate loudness accurately, it is crucial that you correctly
set the Channel Function for each channel. Depending upon the
designated function of each channel, its signal levels will contribute
differently to the Loudness calculation. Refer to the Monitor Mixer
Configuration Menu on page 125.