- Wolf Pro 36" (914) Wall Chimney Hood Planning Information

6
Dimensions in parentheses are in
millimeters unless otherwise specified.
Planning Information
Pro 36" (914) Wall Chimney Hood
MODEL PWC362418(R)
Ducting for Pro wall
chimney hoods.
DUCTWORK INSTALLATION
THROUGH ROOF
24" (610)
DEPTH OF HOOD
ROOF CAP OR REMOTE BLOWER
10" (254) ROUND DUCT
SOFFIT OR CABINET
OR DUCT COVER
NOTE: VERTICAL DISCHARGE ONLY FOR PRO WALL CHIMNEY HOODS.
VERTICAL DISCHARGE
TRANSITION
14"W x 9
3
/4"D TO 10" ROUND
7"H (INCLUDING FLANGES)
30" TO 36"
(762914)
COUNTERTOP
TO BOTTOM OF
VENTILATION HOOD
36" (914)
STANDARD
FLOOR TO
COUNTERTOP
HEIGHT
18" (457)
HEIGHT
OF HOOD
16
3
/4" (425)
TOP OF WOOD
MOUNTING STRIP
WALL HOOD
DUCTING CONSIDERATIONS
Wolf Pro wall chimney ventilation hoods are
shipped without the blower assembly. Internal,
in-line and remote blower assemblies are
available.
IMPORTANT NOTE: Install this ventilation hood
only with a Wolf blower.
Wolf Pro wall chimney hoods have a vertical
discharge location with 10" (254) round duct.
A transition with backdraft damper is included.
The hood will operate most efficiently when
ductwork does not exceed 50' (15 m) in length.
Local building codes may require the use of
make-up air. Consult your local HVAC profes-
sional for specific requirements in your area.
IMPORTANT NOTE: Wolf Pro wall chimney
hoods must be vented to the outside. Use only
metal ductwork.
Refer to the illustration below for ducting
considerations for Pro wall chimney hoods.