Design Guide

wolfappliance.com | 131
SEALED BURNER RANGETOPS
Planning Information
The platform to support the sealed burner rangetop must
include a cutout for electrical and gas supply connections.
Refer to the chart below for minimum base support.
When installing against a combustible surface, a minimum
5"
(127) riser is required for model SRT366, and a minimum
10"
(254) riser is required for 36" and 48" sealed burner
rangetops with a charbroiler or griddle. Follow all minimum
clearances to combustible surfaces shown in the illustration
on the following page.
A Wolf pro ventilation hood is recommended with the sealed
burner rangetop. Refer to page 166 for Pro Ventilation.
A downdraft can be used with models SRT304 and SRT366.
An accessory trim kit is necessary for this installation. Con-
tact an authorized Wolf dealer for details.
INSTALLATION REQUIREMENTS
BASE SUPPORT MIN
30" Rangetop 200 lb (91 kg)
36" Rangetop 250 lb (113 kg)
48" Rangetop 300 lb (136 kg)
PLATFORM MIN
Thickness
3
/4" (19)
ELECTRICAL REQUIREMENTS
Installation must comply with all applicable electrical codes.
Locate the electrical supply within the shaded area shown
in the illustration on the following page. A separate circuit
servicing only this appliance is required.
ELECTRICAL REQUIREMENTS
Electrical Supply grounded, 110/120 VAC, 60 Hz
Service 15 amp dedicated circuit
Receptacle 3-prong grounding-type
Power Cord 6'
(1.8 m)