Design Guide

wolfappliance.com | 159
COOKTOP VENTILATION
Opening Dimensions
UNDER-CABINET HOOD INSERT
Refer to the chart and illustration below for opening dimen-
sions. The cabinet must be able to support a minimum of
100 lb
(45 kg).
OPENING WIDTH
W
24" Hood Insert 19
1
/2" (495)
30" Hood Insert 26
5
/8" (676)
Planning Information
ELECTRICAL REQUIREMENTS
Installation must comply with all applicable electrical codes.
Locate the electrical supply above or in an adjacent cabinet
within reach of the power cord. Refer to the illustration
below. A separate circuit servicing only this appliance is
required.
ELECTRICAL REQUIREMENTS
Electrical Supply grounded, 120 VAC, 60 Hz
Service 15 amp dedicated circuit
Power Cord 4'
(1.2 m)
EE
24" (610) TO 36" (914)
BOTTOM EDGE TO
COUNTERTOP
Electrical location
W
10
1
/4"
(
260
)