Design Guide

80 | Wolf Customer Care 800.222.7820
Planning Information
GAS SUPPLY
Installation must comply with all applicable gas codes.
If local codes permit, a certied, 3'
(.9 m) long,
1
/2" (13) or
3
/4"
(19)
ID exible metal appliance connector is recommended.
Wolf natural gas cooktops will function up to 10,250'
(3124 m)
in altitude without adjustment and LP gas cooktops
will function up to 8,600'
(2621 m). If the installation exceeds
these elevations, contact an authorized Wolf dealer for a
high altitude conversion kit.
GAS REQUIREMENTS
Gas Supply
3
/4" ID line
Gas Inlet
1
/2" NPT male
NATURAL GAS WC
Supply Pressure 5" (12.5 mb)
Min Line Pressure 7" (17.5 mb)
Max Regulator Pressure 14" (34.9 mb), .5 psi (3.5 kPa)
LP GAS WC
Supply Pressure 10" (25 mb)
Min Line Pressure 11" (27.4 mb)
Max Regulator Pressure 14" (34.9 mb), .5 psi (3.5 kPa)
GAS COOKTOPS