Design Guide

Wolf Dual Fuel Ranges 63
wolfappliance.com/specs
Planning Information
A
vailable in four widths, Wolf dual fuel ranges are
designed to fit a 30"
(762), 36" (914), 48" (1219) or 60
1
/4"
(1530) opening.
IMPORTANT NOTE: When installing against a combustible
surface, a minimum 10"
(254) riser is required for a 36"
(914) dual fuel range with charbroiler or griddle and all
48"
(1219) and 60" (1524) models. Follow all minimum clear-
ances to combustible surfaces shown in the installation
illustrations on the following pages.
It is recommended that you use a Wolf pro ventilation
hood or hood liner with the dual fuel range. If the range is
to be installed without ventilation, a 36"
(914) minimum
clearance, 44"
(1118) for charbroiler, from countertop to
combustible materials above the range is required. Refer
to page 105 for pro ventilation.
Oven Specifications
INTERIOR CAPACITY CU FT (
L)
18" (457) Oven 2.5 (71)
30" (762) Oven 4.5 (127)
36" (914) Oven 5.4 (153)
INTERIOR DIMENSIONS WHD
18" (457) Oven 14" (356) 16
1
/2" (419) 19" (483)
30" (762) Oven 25" (635) 16
1
/2" (419) 19" (483)
36" (914) Oven 30" (762) 16
1
/2" (419) 19" (483)
Burner Rating Btu (kW) Btu (kW)
SURFACE BURNERS SIMMER HIGH
Large (3 or 5) 950 (.3) 15,000 (4.4)
Small (1) 325 (.1) 9,200 (2.7)
OPTIONAL FEATURES NATURAL LP
Infrared Charbroiler 16,000 (4.7) 16,000 (4.7)
Infrared Griddle 15,000 (4.4) 13,000 (3.8)
Double Griddle 30,000 (8.8) 26,000 (7.6)
French Top 15,000 (4.4) 15,000 (4.4)
ELECTRICAL REQUIREMENTS
Wolf dual fuel ranges have a terminal block that allows for
a 3-wire or 4-wire installation.
GAS SUPPLY REQUIREMENTS
A gas supply line of
3
/4" (19) rigid pipe must be provided to
the range. If local codes permit, a certified, 3'
(.9 m) long,
1
/2" (13) or
3
/4" (19) ID flexible metal appliance connector is
recommended to connect the units
1
/2" NPT male inlet to
the gas supply line.
Wolf natural gas ranges will function up to an altitude of
10,250'
(3124 m) without adjustment and LP gas ranges will
function up to 8,600'
(2621 m). If the installation exceeds
these elevations, contact your authorized Wolf dealer for
a high altitude conversion kit.
Gas Supply Pressure
NATURAL GAS
Gas Supply Pressure 5" (12.5 mb) WC
Min Line Pressure 7" (17.5 mb) WC
Max Pressure to Regulator 14" (34.9 mb) WC, .5 psi (3.5 kPa)
LP GAS
Gas Supply Pressure 10" (25 mb) WC
Min Line Pressure 11" (27.4 mb) WC
Max Pressure to Regulator 14" (34.9 mb) WC, .5 psi (3.5 kPa)
Electrical Requirements
SINGLE OVEN RANGES
Electrical Supply Grounded, 240/208 V AC, 60 Hz
Service 30 amp dedicated circuit
Total Amps 21
DOUBLE OVEN RANGES
Electrical Supply Grounded, 240/208 V AC, 60 Hz
Service 50 amp dedicated circuit
Total Amps 42.5
RANGES / RANGETOPS
OVENS / WARMING DRAWERS
OUTDOOR GRILLS
VENTILATION
COOKTOPS