Design Guide

Wolf Sealed Burner Rangetops 70
Planning Information
A
vailable in three widths, Wolf sealed burner rangetops
are designed to fit a 30"
(762), 36" (914) or 48" (1219)
opening.
The platform must be able to support 200 lbs
(91 kg) for a
30"
(762) rangetop, 250 lbs (113 kg) for a 36" (914) rangetop
and 300 lbs
(136 kg) for a 48" (1219) rangetop. The platform
must include a cut-out at the right rear for gas supply and
electrical connections.
IMPORTANT NOTE: When installing against a combustible
surface, a minimum 5"
(127) riser is required for model
SRT366, and a minimum 10"
(254) riser is required for
36"
(914) and 48" (1219) sealed burner rangetops with a
charbroiler or griddle. Follow all minimum clearances to
combustible surfaces shown in the installation illustrations
on the following pages.
It is recommended that you use a Wolf pro ventilation
hood or hood liner with the sealed burner rangetop. If the
rangetop is to be installed without ventilation, a 36"
(914)
minimum clearance, 44" (1118) for charbroiler, from coun-
tertop to combustible materials above the rangetop is
required. Refer to page 105 for pro ventilation.
A downdraft can be used with models SRT304 and
SRT366. An accessory trim kit is necessary for this instal-
lation. Contact your authorized Wolf dealer for details.
ELECTRICAL REQUIREMENTS
GAS SUPPLY REQUIREMENTS
A gas supply line of
3
/4" (19) rigid pipe must be provided
to the rangetop. If local codes permit, a certified, 3'
(.9 m)
long,
1
/2" (13) or
3
/4" (19) ID flexible metal appliance con-
nector is recommended to connect the units
1
/2" NPT
female inlet to the gas supply line.
Wolf natural gas rangetops will function up to an altitude
of 10,250'
(3124 m) without adjustment and LP gas range-
tops will function up to 8,600'
(2621 m). If the installation
exceeds these elevations, contact your authorized Wolf
dealer for a high altitude conversion kit.
Gas Supply Pressure
NATURAL GAS
Gas Supply Pressure 5" (12.5 mb) WC
Min Line Pressure 7" (17.5 mb) WC
Max Pressure to Regulator 14" (34.9 mb) WC, .5 psi (3.5 kPa)
LP GAS
Gas Supply Pressure 10" (25 mb) WC
Min Line Pressure 11" (27.4 mb) WC
Max Pressure to Regulator 14" (34.9 mb) WC, .5 psi (3.5 kPa)
Electrical Requirements
SEALED BURNER RANGETOP
Electrical Supply 110/120 V AC, 60 Hz
Service 15 amp dedicated circuit
Receptacle 3-prong grounding-type
Power Cord 6' (1.8 m)