Design Guide

76 | Wolf Customer Care 800.222.7820
Planning Information
A minimum 2" (51) is required from the bottom of the
cooktop to combustible materials. If the cooktop is
installed above an oven, a minimum of ⁄"
(6) is required
between the units.
The contemporary gas cooktop can be mounted flush
with the top of the countertop, or as a standard installation
sitting on top of the countertop surface. If the cooktop is
to be mounted flush with the countertop, a recessed area
surrounding the cooktop cutout must be provided. The
countertop must be able to withstand temperatures up to
300°F
(149°C).
Control knobs for the contemporary gas cooktop are
designed to be mounted on the front face of cabinetry
below the unit. Mounting holes must be drilled through the
cabinet face. Refer to the illustrations on pages 78–79 for
the hole location.
ELECTRICAL REQUIREMENTS
Installation must comply with all applicable electrical codes.
Locate the electrical supply as shown in the illustrations
on the following pages. A separate circuit servicing only
this appliance is required. A ground fault circuit interrupter
(GFCI) is not recommended and may cause interruption of
operation.
ELECTRICAL REQUIREMENTS
Electrical Supply grounded, 120 VAC, 60 Hz
Service 15 amp dedicated circuit
Receptacle 3-prong grounding-type
Power Cord 6' (1.8 m)
GAS SUPPLY
Installation must comply with all applicable gas codes.
If local codes permit, a certified, 3'
(.9 m) long, ⁄" (13) or ⁄"
(19) ID flexible metal appliance connector is recommended.
Wolf natural gas cooktops will function up to 10,250'
(3124 m) in altitude without adjustment and LP gas cook-
tops will function up to 8,600'
(2621 m). If the installation
exceeds these elevations, contact an authorized Wolf
dealer for a high altitude conversion kit.
GAS REQUIREMENTS
Gas Supply ⁄" ID line
Gas Inlet ⁄" NPT male
NATURAL GAS WC
Supply Pressure 5" (12.5 mb)
Min Line Pressure 7" (17.5 mb)
Max Regulator Pressure 14" (34.9 mb), .5 psi (3.5 kPa)
LP GAS WC
Supply Pressure 10" (25 mb)
Min Line Pressure 11" (27.4 mb)
Max Regulator Pressure 14" (34.9 mb), .5 psi (3.5 kPa)
Gas Cooktops