Installation Guide

4 | Wolf Customer Care 800.222.7820
Installation Requirements
A minimum 2" (51) is required from the bottom of the
cooktop to combustible materials.
Clearance is required for the conduit located at the right
rear of induction and electric cooktops. Refer to the illus-
tration below for dimensions.
Refer to the illustrations on pages 6–8 for additional mini-
mum clearances. Installation dimensions are the same for
induction and electric cooktops of the same width.
WARNING
Failure to locate the cooktop without proper clear-
ances will result in a fire hazard.
Specifications
1
1
/4" (32)
2"
(51)
2"
(51)
Conduit clearance
FLUSH INSTALLATION
Contemporary induction and electric cooktops can be
mounted flush with the top of the countertop or as a
frameless standard installation sitting on top of the coun-
tertop surface. If the cooktop is to be mounted flush with
the countertop, a recessed area surrounding the cooktop
cutout must be provided.
An installation kit and instructions required for a flush
installation are provided with the Contemporary cooktop.
CAUTION
A flush installation is intended for granite, solid
surface, or stone countertop surfaces only.
MULTIPLE COOKTOPS
When multiple cooktops or modules are installed side by
side, the countertop cutout width is determined by adding
the width of each unit, then subtracting 1"
(25). Refer to the
illustration below.
IMPORTANT NOTE: Contemporary induction and electric
cooktops are not designed to be installed in combination
with other cooktops.
CUTOUT WIDTH
(COMBINED WIDTH OF COOKTOPS MINUS
1")
19
1
/2"
(495)
CUTOUT
DEPTH
2
1
/2" (64)
2
1
/2" (64)
Countertop cutout