installation guide

4
|
Wolf Customer Care 800.222.7820
Installation Requirements
A minimum 2" (51) is required from the bottom of the
cooktop to combustible materials. If the cooktop is installed
above an oven, a minimum of
1
/4" (6) is required between
units.
The contemporary gas cooktop can be mounted ush with
the top of the countertop, or as a standard installation
sitting on top of the countertop surface. If the cooktop is
to be mounted ush with the countertop, a recessed area
surrounding the cooktop cut-out must be provided. The
countertop must be able to withstand temperatures up to
300°F
(149°C). Wolf downdraft systems cannot be used with
the contemporary gas cooktop.
IMPORTANT NOTE: For ush installations, do not use the
cooktop as a template to create the countertop opening.
Use the countertop cut-out template or specications pro-
vided. Failure to do so may cause damage.
SPECIFICATIONS
Electrical Requirements
Installation must comply with all applicable electrical codes.
Locate the electrical supply as shown in the illustrations
on the following pages. A separate circuit, servicing only
this appliance is required. A ground fault circuit interrupter
(GFCI) is not recommended and may cause interruption of
operation.
ELECTRICAL REQUIREMENTS
Electrical Supply grounded, 120 VAC, 60 Hz
Service 15 amp dedicated circuit
Receptacle 3-prong grounding-type
Power Cord 6'
(1.8 m)