wolf design_guide

wolfappliance.com
|
9
ELECTRICAL
Installation must comply with all applicable electrical codes.
Locate the electrical supply ush with the back wall and
within the shaded area shown in the illustrations on the
following pages. For ease of installation, the electrical
supply for the oven can be placed in an adjacent cabinet
within reach of the conduit.
Performance may be compromised if the electrical supply is
less than 240 volts.
The oven is supplied with a conduit consisting of two
insulated hot lead conductors and a bare ground conductor.
The wiring diagram covering the control circuit is provided
with the oven.
ELECTRICAL REQUIREMENTS—SINGLE OVEN
Electrical Supply grounded, 240/208 VAC, 60 Hz
Service 30 amp dedicated circuit
Conduit 4'
(1.2 m)
Total Amps 22
Max Connected Load 5.4 kW
ELECTRICAL REQUIREMENTS —DOUBLE OVEN
Electrical Supply grounded, 240/208 VAC, 60 Hz
Service 50 amp dedicated circuit
Conduit 5'
(1.5 m)
Total Amps 45
Max Connected Load 10.8 kW
M SERIES OVENS
BUILT-IN OVENS COOKTOPS | COFFEE RANGES | RANGETOPS OUTDOOR GRILLS VENTILATION
Planning Information
The M series oven can be installed in a standard or ush
inset application. If a cooktop is being installed above an
oven, a minimum of
1
/4" (6) is required between units. Loca-
tion of the electrical supply within the oven opening may
require additional cabinet depth.
Finish the edges of the opening. They may be visible when
the door is open.
For standard installations, face trim will overlap stiles and
rails. Refer to the chart below.
For ush inset installations, a minimum
1
/8" (3) reveal is
required on all sides. To ensure consistent reveals, each
corner of the opening must be exactly 90°.
INSTALLATION REQUIREMENTS
BASE SUPPORT MIN
Single Oven 250 lb (115 kg)
Double Oven 400 lb (181 kg)
TRIM OVERLAP
Top 1" (25)
Bottom 0" (0)
Sides
11
/16" (18)
DUAL INSTALLATION
Two 30" single M series ovens can be installed side by side
in a standard or ush inset application. A dual installation kit
is required. To maintain appropriate airow, the ovens must
be installed into one opening. Any cosmetic or structural
material placed between the ovens will impede airow and
is not recommended. Refer to illustrations on pages 14–15.
The dual installation kit is available through an authorized
Wolf dealer. For local dealer information, visit the nd a
showroom section of our website, wolfappliance.com.