Electrical Requirements
Installation must comply with all applicable electrical codes.
Locate the electrical supply as shown in the illustrations
on the following pages. A separate circuit servicing only
this appliance is required. A ground fault circuit interrupter
(GFCI) is not recommended and may cause interruption of
operation.
When multiple cooktops are installed side by side, each
unit must have its own separate recommended electrical
circuit.
ELECTRICAL REQUIREMENTS
INDUCTION
Electrical Supply 3-wire, 240/208 VAC, 60 Hz
Conduit flexible 4' (1.2 m)
ELECTRIC
Electrical Supply 3-wire, 240 VAC, 60 Hz
Conduit flexible 4' (1.2 m)
SERVICE
15" Induction/Electric 20 amp dedicated circuit
24" Induction 30 amp dedicated circuit
30" Induction/Electric 40 amp dedicated circuit
36" Induction/Electric 50 amp dedicated circuit
WARNING
The complete appliance must be properly grounded
at all times when electrical power is applied.
Do not ground appliance with the neutral (white)
house supply wire. A separate ground wire must be
utilized.
If aluminum house supply wiring is utilized, splice
the appliance copper wire to the aluminum house
wiring using special connectors design and agency
certified for joining copper and aluminum. Follow
the connector manufacturer's recommended proce-
dure carefully. Improper connection can result in a
fire hazard.