C O O K T O P V E N T I L AT I O N H O O D S I NSTALLATION I NSTRUCTIONS
As you follow these instructions, you will notice WARNING and CAUTION symbols. This blocked information is important for the safe and efficient installation of Wolf equipment. There are two types of potential hazards that may occur during installation. signals a situation where minor injury or product damage may occur if you do not follow instructions. states a hazard that may cause serious injury or death if precautions are not followed.
W O L F C O O K TO P V E N T I L AT I O N H O O D S I N S TA L L AT I O N R E Q U I R E M E N T S B E F O R E YO U S TA RT IMPORTANT NOTE: This installation must be completed by a qualified installer or Wolf authorized service center technician. IMPORTANT NOTE: Wolf cooktop wall and island hood are recommended for use with Wolf electric and gas cooktops and integrated modules. They are NOT recommended for use with Wolf dual fuel ranges, gas ranges and rangetops.
W O L F C O O K TO P V E N T I L AT I O N H O O D S OV E R A L L D I M E N S I O N S 18" 12" (457) (305) MODEL CTWH30 Overall Width 30" (762) 4 1/2" min Overall Height (excluding chimney) (114) 6 7/8" (175) Overall Height (including chimney) 30 1/2" (775) 30 1/2" TO 48 1/2" 19 1/8" (775 - 1232) OVERALL HEIGHT (486) 48 1/2" (1232) Max Height (full extension) Overall Depth 6 7/8" (175) 30" (762) OVERALL WIDTH 21" (533) OVERALL DEPTH Shipping Weight (shell only) 21" (533) 85 lbs (39 kg)
I N S TA L L AT I O N I N S T R U C T I O N S HOOD P L AC E M E N T Wolf cooktop wall and island hoods come with a telescopic chimney flue that allows you to reach a ceiling height of 8' (2.4 m) to 9' (2.7 m) with a finished look. A flue extension to accommodate 10' (3 m) ceilings is available. Refer to page 12 for optional accessories.
W O L F C O O K TO P V E N T I L AT I O N H O O D S WA L L H O O D I N S T A L L A T I O N I N S TA L L D U C T W O R K DUCTWORK INSTALLATION THROUGH ROOF ROOF CAP OR REMOTE BLOWER – TRANSITION FROM 8" (203) TO 10" (254) DUCT REQUIRED FOR REMOTE BLOWER To reduce the risk of fire, use only metal ductwork. 8" (203) ROUND DUCT IMPORTANT NOTE: Consult a qualified HVAC Engineer for specific ducting applications.
I N S TA L L AT I O N I N S T R U C T I O N S WA L L H O O D I N S TA L L A T I O N ELECTRICAL REQUIREMENTS I N S TA L L M O U N T I N G B R A C K E T S Wolf cooktop wall hoods require a separate, grounded 110/120 V AC, 60 Hz power supply. The service should have its own 15 amp circuit breaker. Locate the electrical supply with a minimum of 12" (305) of 120 V AC power cable within the shaded area shown in the illustration below.
W O L F C O O K TO P V E N T I L AT I O N H O O D S WA L L H O O D I N S TA L L A T I O N I M P O R TA N T N OT E You must follow all National Electrical Code regulations. In addition, be aware of local codes and ordinances when installing your service. ELECTRICAL CONNECTIONS CONNECT DUCTWORK IMPORTANT NOTE: This ventilation hood must be properly grounded. This unit should be installed by a qualified electrician in accordance with all applicable national and local electrical codes.
I N S TA L L AT I O N I N S T R U C T I O N S I S L A N D H O O D I N S TA L L A T I O N I N S TA L L D U C T W O R K To reduce the risk of fire, use only metal ductwork. DUCTWORK INSTALLATION THROUGH ROOF ROOF CAP OR REMOTE BLOWER – TRANSITION FROM 8" (203) TO 10" (254) DUCT REQUIRED FOR REMOTE BLOWER 8" (203) ROUND DUCT IMPORTANT NOTE: Consult a qualified HVAC Engineer for specific ducting applications. Decide where the ductwork will run between the hood and the outside.
W O L F C O O K TO P V E N T I L AT I O N H O O D S I S L A N D H O O D I N S TA L L A T I O N ELECTRICAL REQUIREMENTS The Wolf cooktop island hood requires a separate, grounded 110/120 V AC, 60 Hz power supply. The service should have its own 15 amp circuit breaker. Locate the electrical supply with a minimum of 6' (1.8) of 120 V AC power cable on the ceiling through the top of the hood. You must follow all National Electrical Code regulations.
I N S TA L L AT I O N I N S T R U C T I O N S I S L A N D H O O D I N S TA L L A T I O N M O U N T H O O D TO S U P P O RT F R A M E Mount the hood to the support frame by aligning the four weld screws on the hood to the four holes on the support frame. Use four nuts to secure the hood to the support frame. Refer to the illustration below. Nest the bottom of the telescopic chimney flue into the relief in the hood shell. Make electrical connections.
W O L F C O O K TO P V E N T I L AT I O N H O O D S ACCESSORIES Optional accessories are available through your Wolf dealer. To obtain local dealer information, visit the Locator section of our website, wolfappliance.com. B L OW E R A S S E M B L I E S V E N T I L A T I O N H O O D AC C E S S O R I E S Wolf cooktop wall and island hoods are shipped without the blower assembly. Wolf internal or remote blower assemblies are available as sales accessories through your Wolf dealer.
I N S TA L L AT I O N I N S T R U C T I O N S INTERNAL B L OW E R S R E M OT E B L O W E R S I N T E R N A L B L O W E R I N S T A L L AT I O N R E M O T E B L O W E R I N S TA L L AT I O N IMPORTANT NOTE: For mounting and installation of the internal blower, refer to the specific installation instructions provided with each blower. IMPORTANT NOTE: For mounting and installation of the remote blower, refer to the specific installation instructions provided with each blower. 1) Remove the hood filters.
W O L F C O O K TO P V E N T I L AT I O N H O O D S R E M OT E B L O W E R S IMPORTANT NOTE: Before turning the power on to the ventilation hood, make sure the blower is in the OFF position. R E M OT E B L OW E R W I R I N G 1) Remove the cover from the front of the electrical box. Remove the electrical box knockout that faces the hood's discharge collar. 2) Disconnect the red and black or white wires using a flat-blade screwdriver. Refer to illustration A below.
I N S TA L L AT I O N I N S T R U C T I O N S TROUBLES H O OT I N G IMPORTANT NOTE: If the cooktop ventilation hood does not operate properly, follow these troubleshooting steps: Verify that power is being supplied to the ventilation hood. Check electrical connections to ensure that the installation has been completed correctly. Refer to the Troubleshooting Guide in the Wolf Cooktop Ventilation Hoods Use & Care Information.
W O L F A P P L I A N C E C O M PA N Y, L L C 807574 9 / 2005 P. O. B OX 4 4 8 4 8 MADISON, WI 53744 800-332-9513 W O L FA P P L I A N C E .