Specifications
89
Dimensions in parentheses are in
millimeters unless otherwise specified.
BLOWER CONSIDERATIONS
Wall hood Models W302210I and W362210I
come with internal blowers. All other Pro wall
and island hoods are shipped without the blower
assembly. Internal, in-line and remote blower
assemblies are available. For Pro wall and island
hoods, the remote blower can be mounted on
the roof or an exterior wall.
Hood liner Model L282212I comes with an
internal blower. All other Pro hood liners are
shipped without the blower assembly. Internal,
in-line and remote blower assemblies are avail-
able. For Pro hood liners, the remote blower can
be mounted on the roof or exterior wall.
The blower assemblies are quite varied, and
depending on the amount of air you want to
move and the length of the duct run, you have
many options.
DUCTWORK INSTALLATION
THROUGH ROOF
22" (559)
DEPTH OF HOOD
8" ROUND DUCT
SOFFIT OR CABINET
OR DUCT COVER
REMOTE BLOWER
*HORIZONTAL DISCHARGE APPLICABLE ON LOW-PROFILE WALL HOODS
(EXCLUDING W302210I AND W362210I) USING A REMOTE BLOWER. LOW-PROFILE WALL
HOODS WITH AN INTERNAL OR IN-LINE BLOWER MUST USE VERTICAL DISCHARGE.
DUCTWORK INSTALLATION
THROUGH WALL
DISCHARGE COLLAR
HORIZONTAL
DISCHARGE*
VERTICAL DISCHARGE
TRANSITION
17
3
/4"W x 4
1
/4"D TO 8" ROUND
9
3
/8"H (INCLUDING FLANGES)
30" TO 36"
(762–914)
COUNTERTOP
TO BOTTOM OF
VENTILATION HOOD
36" (914)
STANDARD
FLOOR TO
COUNTERTOP
HEIGHT
10" (254)
HEIGHT OF HOOD
WALL HOOD
ROOF CAP OR REMOTE BLOWER –
TRANSITION FROM 8" (203) TO 10" (254) DUCT
REQUIRED FOR REMOTE BLOWER
DUCTWORK INSTALLATION
THROUGH ROOF
24" (610)
DEPTH OF HOOD
ROOF CAP OR REMOTE BLOWER
10" ROUND DUCT
SOFFIT OR CABINET
OR DUCT COVER
WALL CAP
OR REMOTE BLOWER
*HORIZONTAL DISCHARGE IS APPLICABLE ON 24" (610) DEEP WALL HOODS USED WITH
WBLOWER-60INT, WBLOWER-120INT OR ANY WOLF REMOTE BLOWER. WBLOWER-90INT
AND IN-LINE BLOWERS ARE NOT FOR USE IN HORIZONTAL DISCHARGE APPLICATIONS.
DUCTWORK INSTALLATION
THROUGH WALL
DISCHARGE COLLAR
HORIZONTAL
DISCHARGE*
VERTICAL DISCHARGE
TRANSITION
22
1
/4"W x 9"D TO 10" ROUND
10"H (INCLUDING FLANGES)
30" TO 36"
(762–914)
COUNTERTOP
TO BOTTOM OF
VENTILATION HOOD
36" (914)
STANDARD
FLOOR TO
COUNTERTOP
HEIGHT
18" (457)
HEIGHT OF HOOD
WALL HOOD
A straight, short duct run with a limited number
of elbows and transitions will allow the ventila-
tion hood to perform most efficiently. The
Pro wall and island hoods will operate most
efficiently when ductwork does not exceed 50'
(15 m) in length.
A remote mounted blower will minimize the
amount of blower noise, but will not eliminate
the noise completely.
IMPORTANT NOTE: Install this ventilation hood
or hood liner only with a Wolf blower.
Refer to the Pro ventilation recommendations on
pages 95–98.
Refer to the illustrations below for ducting
considerations for the Pro low-profile and 24"
(610) deep wall hoods.
DUCTING CONSIDERATIONS
Pro Low-Profile Wall Hoods Pro 24" (610) Deep Wall Hoods
WOLF PRO VENTILATION
INSTALLATION
Refer to installation
instructions shipped
with each Wolf
product for detailed
specifications.