Specifications
63
Dimensions in parentheses are in
millimeters unless otherwise specified.
WOLF GAS BBQ GRILLS
PLANNING INFORMATION
It goes without saying that the BBQ grill
mounted on the free-standing cart takes very
little planning from a design perspective.
However, there are provisions you need to take
into account when planning for a built-in
application.
When choosing a permanent built-in location for
your Wolf gas BBQ grill, keep the gas lines as
short as possible. Allow for an adequate supply
of fresh air for proper combustion and ventila-
tion. The BBQ grill should not be exposed to the
wind, but never locate the grill in an enclosed
area.
The Wolf gas BBQ grill is designed for easy
placement into a built-in enclosure. For a
combustible enclosure, use the Wolf-approved
insulated jacket and maintain minimum clear-
ances to combustible surfaces. Built-in installa-
tions require a deck to support the BBQ grill.
The supporting deck should be level and strong
enough to support 400 lbs (181 kg).
Wolf gas BBQ grills come in 36" (914) and 48"
(1219) widths. Specifications on the following
pages provide overall dimensions, finished rough
opening dimensions and installation specifics for
each size of gas BBQ grill. We have minimized
the information contained in the illustrations,
concentrating on the critical information you
must plan into your installation.
IMPORTANT NOTE: The Wolf gas BBQ grill must
be specified natural or LP gas at the time of
order. The gas type cannot be converted.
ELECTRICAL | GAS REQUIREMENTS
The Wolf gas BBQ grill requires a 110/120 V
electrical supply to operate the rotisserie motor.
The 6' (1.8 m) power supply cord provided with
the grill is equipped with a 3-prong, grounded
plug for protection against shock hazard. The
service should have its own 15 amp circuit
breaker.
IMPORTANT NOTE: A ground fault circuit
interrupter (GFCI) is not recommended and may
cause interruption of operation.
Locate electrical and gas supply within the
shaded area shown in the Installation Specifica-
tions illustration for your built-in model.
Wolf gas BBQ grills are designed to operate on
natural gas at 5" (127) WC (water column)
pressure or LP gas at 10" (254) WC pressure.
The maximum gas supply pressure to the regula-
tor should never exceed 14" (356) WC, .5 psi
(3.5 kPa).
Wolf recommends the use of a
1
/2" (13) I.D.
commercial-type flex hose; this is the minimum
size that may be used. All plumbing to the flex
hose must be
3
/4" (19) minimum I.D. pipe.
IMPORTANT NOTE: A separate external gas
shut-off valve must be located near the range
in an accessible location.
You must follow all National Electrical Code and
gas regulations. In addition, be aware of local
codes and ordinances when installing your
services.
BURNER RATING
Gas BBQ Grills
Grill Burners 10,000 Btu/hr
(per burner) (2.9 kW)
Side Burners (2) 16,000 Btu/hr
(per burner) (4.7 kW)
Infrared Burner 8,000 Btu/hr*
(2.3 kW)
Infrared Burner 9,000 Btu/hr
(2.6 kW)
*Models BBQ242BI and BBQ242C only.
ACCESSORIES
Optional accessories
are available
through your Wolf
dealer. To obtain
local dealer
information, visit
the Locator section
of our website,
wolfappliance.com.