Specifications

85
Dimensions in parentheses are in
millimeters unless otherwise specified.
WOLF PRO VENTILATION
DUCTING CONSIDERATIONS
Pro wall and island hoods and hood liners will
operate most efficiently when ductwork does
not exceed 50' (15 m) in length.
Local building codes may require the use of
make-up air. Consult your local HVAC profes-
sional for specific requirements in your area.
Refer to the Pro ventilation recommendations
on pages 87–90.
12" (305)
HEIGHT OF LINER
HOOD LINER
DUCTWORK INSTALLATION
THROUGH ROOF
8" ROUND DUCT (L282212I)
10" ROUND DUCT (ALL OTHER LINERS)
SOFIT OR CABINET
OR DUCT COVER
VERTICAL DISCHARGE ONLY FOR VENTILATION HOOD LINERS.
VERTICAL DISCHARGE
22
1
/2" (572)
DEPTH OF LINER
DECORATIVE HOOD
30" TO 36"
(762–914)
COUNTERTOP
TO BOTTOM OF
DECORATIVE HOOD
36" (914)
STANDARD
FLOOR TO
COUNTERTOP
HEIGHT
TRANSITION
17
3
/4"W x 4
1
/4"D TO 8" ROUND
9
3
/8"H (L282212I)
22
1
/4"W x 9"D TO 10" ROUND
10"H (ALL OTHER LINERS)
DIMENSIONS INCLUDE FLANGES
ROOF CAP OR REMOTE BLOWER –
TRANSITION FROM 8" (203) TO 10" (254) DUCT
REQUIRED FOR REMOTE BLOWER
DUCTING CONSIDERATIONS
Pro Hood Liners
24
1
/2
"
(622)
15
1
/2
"
(394)
28
1
/4
"
(718)
20
3
/4
"
(527)
24
3
/4
"
(629)
14"
(356)
4
3
/4
"
(121)
10" (254)
Diameter
14
3
/4
"
(375)
29
1
/2
"
(749)
29
1
/2
"
(749)
18" (457)
22"
(559)
10
1
/8
"
(257)
7
1
/4
"
(184)
10"
(254)
10" (254)
Diameter
BLOWER-60REM
and BLOWER-90REM
14
3
/4
"
(375)
29
1
/2
"
(749)
29
1
/2
"
(749)
21" (533)
25"
(635)
10
3
/8
"
(264)
7
1
/4
"
(184)
10"
(254)
10" (254)
Diameter
BLOWER-150REM
BLOWER-120REM
REMOTE BLOWERS
With a few exceptions where internal blowers
are included, Wolf ventilation hoods and down-
drafts are shipped without the blower assembly.
Wolf internal and remote blowers are available as
sales accessories through your Wolf dealer.
Remote blowers can be mounted on the roof or
in some cases, on an exterior wall. Refer to the
illustrations below for dimensions. Installation
instructions shipped with each Wolf ventilation
product provide detailed specifications. These
instructions can also be found on the Wolf
website at wolfappliance.com.
Wolf remote blower Models BLOWER-60REM,
BLOWER-90REM, BLOWER-120REM and
BLOWER-150REM are for use with Wolf cooktop
hoods, downdraft systems and Pro ventilation
hoods and hood liners. Refer to pages 86–90 for
ventilation recommendations.
ACCESSORIES
Optional accessories
are available
through your Wolf
dealer. To obtain
local dealer
information, visit
the Locator section
of our website,
wolfappliance.com.