Installation Guide

4
|
Wolf Customer Care 800.222.7820
SPECIFICATIONS
Electrical
Installation must be electrically grounded in accordance
with local codes or, in the absence of local codes, with the
National Electrical Code, ANSI/NFPA 70.
Locate the electrical supply as shown in the illustrations on
pages 5–6. A separate circuit, servicing only this appliance
is required. A ground fault circuit interrupter (GFCI) is not
recommended and may cause interruption of operation.
Certain installations may require that the electrical supply be
placed in an adjacent cabinet.
ELECTRICAL REQUIREMENTS
Electrical Supply grounded, 120 VAC, 60 Hz
Service 15 amp dedicated circuit
Receptacle 3-prong grounding-type
Power Cord 2
1
/2' (.8 m)
GROUNDING INSTRUCTIONS
This appliance must be grounded. In the event of an elec-
trical short circuit, grounding reduces the risk of electric
shock by providing an escape wire for the electric current.
This appliance is equipped with a cord having a grounding
wire with a grounding plug. The plug must be plugged into
an outlet that is properly installed and grounded.
WARNING
Improper grounding can result in a risk of electric
shock. Consult a qualied electrician if the grounding
instructions are not completely understood, or if
doubt exists as to whether the appliance is properly
grounded.
Do not use an extension cord. If the power supply cord
is too short, have a qualied electrician install an outlet
near the appliance.
Installation Requirements
For installation with a Wolf cooktop, a minimum 25
1
/8" (638)
deep at countertop is required.
For installation with a sealed burner rangetop, an accessory
trim kit is required. Contact your authorized Wolf dealer for
details. For local dealer information, visit the nd a show-
room section of our website, wolfappliance.com.
The remote-mounted control module can be positioned
horizontally or vertically. It must be located within 9'
(2.7 m)
of the downdraft assembly and a minimum 3"
(76) from the
edge of the cooktop or rangetop cut-out.
BLOWERS
CAUTION
For use with Wolf 600 CFM internal blower and remote
blowers rated maximum 3 amps.
Internal, in-line and remote blower assemblies are available
through your authorized Wolf dealer. For local dealer infor-
mation, visit the nd a showroom section of our website,
wolfappliance.com.
Internal blowers include a 6"
(152) round discharge, can be
front or rear mounted and can be discharged in any direc-
tion by rotating the blower box. In-line and remote blowers
have a 10"
(254) round discharge and can be discharged
from the front or rear.
DUCTWORK
WARNING
TO REDUCE THE RISK OF FIRE, USE ONLY METAL
DUCTWORK.
Wolf downdrafts must be vented outside.
Consult a qualied HVAC professional for specic installa-
tion and ducting applications.
The downdraft will operate most efciently with the fewest
number of elbows and transitions and when ductwork does
not exceed 40'
(12 m).