Planning Information
The speed oven can be installed in a standard or flush inset
application.
Finish the edges of the opening. They may be visible when
the door is open.
For standard installations, the face trim will overlap stiles
and rails. Refer to the chart below.
For flush inset installations, a minimum ⁄"
(3) reveal is
required on all sides. To ensure consistent reveals, each
corner of the opening must be exactly 90°.
If the speed oven is installed above or below a Wolf E
series oven in a flush inset application, a ⁄"
(6) reveal is
required.
INSTALLATION REQUIREMENTS
BASE SUPPORT MIN
24" (610) Model 125 lb (57 kg)
30" (762) Model 125 lb (57 kg)
TRIM OVERLAP 24" MODEL 30" MODEL
Top ⁄" (5) ⁄" (5)
Bottom 0" (0) 0" (0)
Sides ⁄" (18) 3⁄" (98)
ELECTRICAL REQUIREMENTS
Installation must comply with all applicable electrical codes.
Locate the electrical supply as shown in the illustrations on
the following pages. The receptacle may also be located
in an adjacent cabinet within reach of the power cord. A
separate circuit, servicing only this appliance is required. A
ground fault circuit interrupter (GFCI) is not recommended
and may cause interruption of operation. Refer to the illus-
tration below for minimum power cord plug clearance.
ELECTRICAL REQUIREMENTS
Electrical Supply grounded, 240/208 VAC, 60 Hz
Service 15 amp dedicated circuit
Receptacle NEMA 6-20R grounding type
Power Cord 6' (1.8 m)
NEMA
PLUG
GROUNDED
NEMA RECEPTACLE
1" (25)
MINIMUM
CORD
CLEARANCE
NEMA 6-20R receptacle
Power cord clearance