Inline Blower Install

Page 4
99043890C
WARNING: To reduce the risk of electric shock,
disconnect from power supply before servicing.
To clean blower assembly: Remove access panel, unplug blower
from housing, remove blower mounting nuts, and carefully remove
blower from housing. Use appropriate vacuum attachment or a soft
cloth and mild soap or detergent to clean blower discharge area and
wheel. DO NOT ALLOW WATER TO ENTER MOTOR. Make sure
blower assembly is completely dry before reinstalling.
Motor is permanently lubricated. Do not oil or disassemble motor.
USE AND CARE
Follow wiring instructions packed with range hood, and adhere to
all local and state codes, and the National Electrical Code.
ATTACH POWER CORD TO
HOOD
Some hoods require the use of a separate power cord and strain
relief bushing (included), for proper wiring of in-line blowers. Please
refer to the hood manual for proper installation instructions.