Design Guide

32 | Wolf Customer Care 800.222.7820
Planning Information
If a cooktop is being installed above an oven, a minimum
of ⁄"
(6) is required between the units. The location of
the electrical supply within the oven opening may require
additional cabinet depth.
Finish the edges of the opening. They may be visible when
the door is open.
For standard installations, the face trim will overlap stiles
and rails. Refer to the chart below.
INSTALLATION REQUIREMENTS
BASE SUPPORT MIN
36" Single Oven 250 lb (113 kg)
TRIM OVERLAP
Top ⁄" (5)
Bottom ⁄" (3)
Sides ⁄" (14)
ELECTRICAL REQUIREMENTS
Installation must comply with all applicable electrical codes.
Locate the electrical supply flush with the back wall and
within the shaded area shown in the illustration on the fol-
lowing page. For ease of installation, the electrical supply
for the oven can be placed in an adjacent cabinet within
reach of the conduit.
Performance may be compromised if the electrical supply
is less than 240 volts.
The oven is supplied with a conduit consisting of two
insulated hot lead conductors and a bare ground con-
ductor. The wiring diagram covering the control circuit is
provided with the oven.
ELECTRICAL REQUIREMENTS
Electrical Supply grounded, 240/208 VAC, 60 Hz
Service 30 amp dedicated circuit
Conduit 3' (.9 m)
Total Amps 21
Max Connected Load 5.1 kW
L Series Oven