E series ovens can be installed in a standard or ush inset
application. If a cooktop is being installed above an oven, a
minimum of
1
/4" (6) is required between the units. The loca-
tion of the electrical supply within the oven opening may
require additional cabinet depth.
Finish the edges of the opening. They may be visible when
the door is open.
For standard installations, the face trim will overlap stiles
and rails. Refer to the chart below.
For ush inset installations, a minimum reveal is required
on all sides. Refer to the chart below. To ensure consistent
reveals, each corner of the opening must be exactly 90°.
INSTALLATION REQUIREMENTS
BASE SUPPORT MIN
24" Oven 150 lb (68 kg)
30" Single Oven 250 lb (113 kg)
30" Double Oven 400 lb (181 kg)
TRIM OVERLAP 24" OVEN 30" OVEN
Top
1
/4" (6)
1
/2" (13)
Bottom 0" (0)
1
/8" (3)
Sides
11
/16" (17)
11
/16" (17)
REVEAL MIN
24" Oven
1
/8" (3)
30" Oven
1
/4" (6)