Design Guide

116 | Wolf Customer Care 800.222.7820
Planning Information
The platform to support the Sealed Burner Rangetop must
include a cutout for electrical and gas supply connections.
Refer to the chart below for minimum base support.
When installing against a combustible surface, a mini-
mum 5"
(127) riser is required for model SRT366, and a
minimum 10"
(254) riser is required for 36" and 48" Sealed
Burner Rangetops with a charbroiler or griddle. Follow all
minimum clearances to combustible surfaces shown in
the illustration on the following page. Models SRT362W
and SRT484W cannot be installed against a combustible
surface.
A Wolf Pro Ventilation Hood is recommended with the
sealed burner rangetop. Refer to page 148 for Pro Ventila-
tion.
A downdraft can be used with Models SRT304 and SRT366.
An accessory trim kit is necessary for this installation. Con-
tact an authorized Wolf dealer for details.
INSTALLATION REQUIREMENTS
BASE SUPPORT MIN
30" Rangetop 200 lb (91 kg)
36" Rangetop 250 lb (113 kg)
48" Rangetop 300 lb (136 kg)
PLATFORM MIN
Thickness ⁄" (19)
ELECTRICAL REQUIREMENTS
Installation must comply with all applicable electrical codes.
Locate the electrical supply within the shaded area shown
in the illustration on the following page. A separate circuit
servicing only this appliance is required.
ELECTRICAL REQUIREMENTS
Electrical Supply grounded, 110/120 VAC, 60 Hz
Service 15 amp dedicated circuit
Receptacle 3-prong grounding-type
Power Cord 6' (1.8 m)
GAS SUPPLY
Installation must comply with all applicable gas codes.
If local codes permit, a certified, 3'
(.9 m) long, ⁄" (13) or ⁄"
(19) ID flexible metal appliance connector is recommended.
Wolf natural gas rangetops will function up to 10,250'
(3124 m) in altitude without adjustment and LP gas ran-
getops up to 8,600'
(2621 m). If the installation exceeds
these elevations, contact an authorized Wolf dealer for a
high altitude conversion kit.
GAS REQUIREMENTS
Gas Supply ⁄" ID line
Gas Inlet ⁄" NPT female
NATURAL GAS WC
Supply Pressure 5" (12.5 mb)
Min Line Pressure 7" (17.5 mb)
Max Regulator Pressure 14" (34.9 mb), .5 psi (3.5 kPa)
LP GAS WC
Supply Pressure 10" (25 mb)
Min Line Pressure 11" (27.4 mb)
Max Regulator Pressure 14" (34.9 mb), .5 psi (3.5 kPa)
Sealed Burner Rangetops