Design Guide

112 | Wolf Customer Care 800.222.7820
Planning Information
When installing against a combustible surface, a minimum
20"
(508) riser is required. Follow all minimum clearances
to combustible surfaces shown in the illustration on the
following page.
A Wolf pro ventilation hood is recommended with the gas
range. Refer to page 152 for Pro Ventilation.
ELECTRICAL REQUIREMENTS
Installation must comply with all applicable electrical codes.
Locate the electrical supply flush with the wall or floor and
within the shaded area shown in the illustration on the fol-
lowing page. A separate circuit servicing only this appliance
is required.
ELECTRICAL REQUIREMENTS
Electrical Supply grounded, 110/120 VAC, 60 Hz
Service 15 amp dedicated circuit
Receptacle 3-prong grounding-type
Power Cord 6' (1.8 m)
GAS SUPPLY
Installation must comply with all applicable gas codes.
If local codes permit, a certified, 3'
(.9 m) long, ⁄" (13) or ⁄"
(19) ID flexible metal appliance connector is recommended.
Wolf natural gas ranges will function up to 8,600'
(2621 m)
in altitude without adjustment. If the installation exceeds
this elevation, contact an authorized Wolf dealer for a high
altitude conversion kit. LP models do not require conver-
sion.
GAS REQUIREMENTS
Gas Supply ⁄" ID line
Gas Inlet ⁄" NPT female
NATURAL GAS WC
Supply Pressure 5" (12.5 mb)
Min Line Pressure 7" (17.5 mb)
Max Regulator Pressure 14" (34.9 mb), .5 psi (3.5 kPa)
LP GAS WC
Supply Pressure 10" (25 mb)
Min Line Pressure 11" (27.4 mb)
Max Regulator Pressure 14" (34.9 mb), .5 psi (3.5 kPa)
Gas Ranges